Generac 101 9-3 Portable Generator User Manual


 
5
7500EXL Extended Life Generator
KNOW YOUR GENERATOR
Read this Operator’s Manual and safety rules before operating your generator.
Compare this illustration with your generator to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
12 Volt DC Receptacle — Use this receptacle with
battery charge cables to charge a 12 Volt battery.
120 Volt AC, 20 Amp Duplex Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, single phase, 60 Hz electrical lighting, appliance,
tool and motor loads.
120 Volt AC, 30 Amp Locking Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May
be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 50 Amp Receptacle — May be used
to supply electrical power for the operation of 240 Volt AC,
50 Amp, single phase, 60 Hz electrical loads.
Air Cleaner — Protects engine by filtering dust and
debris out of intake air.
Choke Lever — Used when starting a cold engine.
Circuit Breakers (AC) — Each receptacle is provided
with a "push to reset" circuit breaker to protect the
generator against electrical overload.
Fuel Tank — Capacity of seven (7) U.S. gallons.
Electric Start Switch — Press to start the engine.
Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
Idle Control Switch — The idle control runs the engine
at normal (high) speeds when there is a load present and
runs the engine at idle (low) speeds when a load is not
present.
Oil Fill Cap — Add oil to engine here.
Recoil Starter — Used to start the engine manually.
Run/Stop Switch — Must be in “Run” position to start
engine. Set to “Stop” to stop a running engine.
Spark Arrester Muffler — Exhaust muffler lowers engine
noise and is equipped with a spark arrester screen.
120 Volt AC, 20 Amp
Duplex Receptacle
Idle Control Switch
Recoil Starter
Run/Stop Switch
Choke Lever
120/240 Volt AC,
30 Amp Locking
Receptacle
120/240 Volt AC,
50 Amp Receptacle
Circuit Breakers (AC)
120 Volt AC, 30 Amp
Locking Receptacle
12 Volt DC
Receptacle
Spark Arrester Muffler
Electric Start Button
Grounding Fastener
Air Cleaner
Fuel Tank
Oil Fill Cap