Generac 005734-0 Portable Generator User Manual


 
13
3.1 PERFORMING SCHEDULED
MAINTENANCE
It is important to perform service as specified in the Maintenance
Schedule for proper generator operation, and to ensure that the generator
complies with the applicable emission standards for the duration of its
useful life. Service and repairs may be performed by any capable person
or repair shop. Additionally, emissions critical maintenance must be
performed as scheduled in order for the Emissions Warranty to be valid.
Emissions critical maintenance consists of servicing the air filter and spark
plugs in accordance with the Maintenance Schedule.
3.2 MAINTENANCE SCHEDULE
Follow the calendar intervals. More frequent service is required when
operating in adverse conditions noted below.
Check Oil Level At Each Use
Change Oil ‡ *Every 100 hours or Every Season
Check Valve Clearance ***Every Season
Service Air Filter ** Every 200 hours or Every Season
Replace Spark Plug Every Season
Change oil after first 30 hours of operation then every season.
* Change oil and oil filter every month when operating under heavy load or in high
temperatures.
** Clean more often under dirty or dusty operating conditions. Replace air filter
parts if they cannot be adequately cleaned.
*** Check valve clearance and adjust if necessary after first 50 hours of
operation and every 100 hours thereafter.
3.3 PRODUCT SPECIFICATIONS
3.3.1 GENERATOR SPECIFICATIONS
MODEL 15 KW 17.5 KW
Rated Max. Power 15.0 kW 17.5 kW
Surge Power 22.5 kW 26.25 kW
Rated AC Voltage 120/240 120/240
Rated Max AC Load
Current @ 240V 62.5 Amps 72.9 Amps
Current @ 120V 125.0 Amps 145.8 Amps
Rated Frequency 60 Hz @ 3600 RPM 60 Hz @ 3600 RPM
Phase Single Phase Single Phase
Rated DC Voltage 12 Volts 12 Volts
Rated Max DC Load
Current @ 12 Volts 10 Amperes 10 Amperes
Weight 373 lbs. 400 lbs.
3.3.2 ENGINE SPECIFICATIONS
Rated Horsepower @ 3600 RPM 30
Displacement 992cc
Spark Plug Type Champion RC14YC or Equivalent
Spark Plug Gap 0.040 inch or (1.01 mm)
Gasoline Capacity 16 U.S. gallons
Oil Type Summer – SAE 30, Winter
5W-30 Synthetic or 10W-30
Oil Capacity w/ Filter Change = 1.7 Qts., w/o
Filter Change = 1.4 Qts.
Run Time/Fuel Consumption-1/2
Load
10 Hours / 1.6 gallons per hour
3.3.3 EMISSIONS INFORMATION
The Environmental Protection Agency (and California Air Resource Board
for generators certified to CA standards) require(s) that this generator
comply with exhaust and evaporative emission standards. Locate the
emissions compliance decal on the engine to determine what standards
the generator meets. This generator is certified to operate on gasoline. The
emission control system consists of the following:
Air Induction System
~ Intake Pipe / Manifold
~ Air Cleaner
Fuel System
~ Carburetor
~ Fuel Tank / Cap
~ Fuel Lines
~ Evaporative Vent Lines
~ Carbon Canister (for CA engines only)
Ignition System
~ Spark Plug
~ Ignition Module
Exhaust System
~ Exhaust Manifold
~ Muffler
~ Catalyst (for CA engines only).
3.4 GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been
subjected to operator abuse or negligence. To receive full value from the
warranty, the operator must maintain the generator as instructed in this
manual.
Some adjustments will need to be made periodically to properly maintain
the generator.
All adjustments in the Maintenance section of this manual should be made
at least once each season. Follow the requirements in the "Maintenance
Schedule" chart.
NOTE:
Once a year, replace the spark plug and replace the air filter. A new
spark plug and clean air filter assure proper fuel-air mixture and help
the engine run better and last longer.
Maintenance