Gardena 1820 Outdoor Timer User Manual


 
9
7. Changing the Battery / Testing the Battery
A
To ensure the Water Timer runs safely, only a 9 V alkali-
manganese battery (alkaline) type IEC 6LR61 must be used.
If the battery voltage falls below a
certain level the Batt. indicator appears.
It is possible to initiate watering manually
even if the battery capacity is too low
(valve no longer opens), but programmed
watering times, however, are not initiated.
Even if the battery capacity is too low to run a program, if the valve is
open it will be closed.
The battery voltage is tested during the opening and the closing pulse.
In this way you can test the capability of the battery at any time. To do
this, press two times the On/Off-man. key. If the valve closes and the
Batt. indicator does not appear then the battery is functioning. If the
display disappears and only the Batt. indicator appears, the battery has
to be changed.
A
Previously set data is lost when replacing the battery.
Program the Water Timer subsequently again.
For notes on changing the battery see “Inserting the Battery”.
8. Notes on Safety and Operation
.
The minimum water output to ensure that the Water Computer
functions correctly is 20-30 l/h.
For example, at least 10 x 2-litre Drip Heads are required to
control the Micro-Drip-System.
.
To prevent water penetrating the battery compartment the Water
Timer must only be mounted in a perpendicular position with
the sleeve nut pointing upwards.
.
Program the Water Timer with the tap turned off. In this way
you can avoid getting wet when trying out the manual On/Off
function. You can remove the control unit from the housing to
program the Water Timer.
.
The Water Timer must only be used outdoors.
Warning! The Water Timer must not be used indoors.
.
The Water Timer must be stored in a dry place away from frost
before the frosty season begins.
.
The max. temperature for the water flow is 40 °C.
8
You can start or end the watering prematurely at any time by pressing the
man. key. The watering time is then 30 minutes.
Read / Change Program
To check the data, you can repeatedly press the O.K. key to run through
the program levels. The levels are selected and checked consecutively.
This does not interrupt the current program cycle.
To change the data, proceed as described above.
Program Overview
Program
Cycle Duration
number
00
No program active
01
6 hours (4 times daily) 3 minutes
02
12 hours (twice daily) 3 minutes
03
12 hours (twice daily) 15 minutes
04
24 hours (once a day) 3 minutes
05
24 hours (once a day) 5 minutes
06
24 hours (once a day) 30 minutes
07
24 hours (once a day) 1 hour
08
2 days 5 minutes
09
2 days 30 minutes
10
2 days 1 hour
11
3 days 30 minutes
12
3 days 1 hour
13
7 days 1 hour
14
7 days 2 hours
Manual, programming-independent On/Off (man.)
Before and after entering data, you can operate the GARDENA Water
Timer electronic T 14 e manually, independent of the programmed data.
To do this, press the man. key.
Press the MAN key once to activate watering for a maximum of 30 minutes
(LCD: On). Press the man. key again to end watering.
·
Batt.
On
·
Off
·
28
.
.
883
·
Time
·
Start
·
Cycle