Ferris Industries IS4500ZC28D61 Lawn Mower User Manual


 
24
Regular Maintenance
BATTERY MAINTENANCE
NOTE: This unit is equipped with a maintenance-free
BCI58 battery)
Cleaning the Battery and Cables
1. Disconnect the cables from the battery, negative
cable first (A, Figure 24).
2. Remove the battery retainer strap (C).
3. Remove the battery and clean the tray and surround-
ing areas with a solution of baking soda and water.
4. Clean the battery terminals and cable ends with a
wire brush until shiny.
5. Reinstall the battery and reattach the battery cables,
positive cable first (B).
6. Secure the battery with the retainer strap (C).
7. Coat the cable ends and battery terminals with petro-
leum jelly or non-conducting grease.
Figure 24. Battery Compartment
A. Negative (-) Cable & Terminal
B. Positive (+) Cable & Terminal
C. Retainer Strap
WARNING
Be careful when handling the battery. Avoid
spilling electrolyte. Keep flames and sparks away
from the battery.
When removing or installing battery cables,
disconnect the negative cable FIRST and
reconnect it LAST. If not done in this order, the
positive terminal can be shorted to the frame by a
tool.
FRONT
C
B
A
ANTI-SCALP DECK CASTERS
The anti-scalp deck casters (A, Figure 25) will aid in pre-
venting the mower deck from scalping or gouging the
turf while mowing or turning.
The casters can be adjusted in 1/2” (1,3 cm) increments
with the spacers (B). The desired position is just below
the leading edge of the deck.
IMPORTANT NOTE: These casters are not intended to
be in contact with the ground at all times. If you are
mowing at a low cut height, adjust the casters up to pre-
vent the casters from carrying the weight of the deck.
A
C
B
B
Figure 25. Anti-Scalp Deck Casters
A. Deck Caster
B. Spacer
C. Lynch Pin