Excell Precision XR2750 Pressure Washer User Manual


 
13- ENG
A12338
4. Remove the high-pressure nozzle
from the spray wand. Remove any
obstructions with the nozzle
cleaning tool provided and
backflush with clean water.
5. Direct water supply into spray
wand to backflush loosened
particles for 30 seconds.
6. Reassemble the nozzle to the
wand.
7. Reconnect spray wand to gun and
turn on water supply.
8. Start pressure washer and place
spray wand into high pressure
setting to test.
HOW TO CLEAN THE WATER
INLET FILTER
This screen filter should be checked
periodically and cleaned if necessary.
1. Remove filter by
grasping end and
removing it from
water inlet of
pump as shown.
2. Clean filter by flushing it with
water on both sides.
3. Re-insert filter into water inlet of
pump. NOTE: Cone side faces
out.
NOTE: Do not operate pressure
washer without filter properly installed.
Filter Screen
MAINTENANCE
When performing
maintenance, you
may be exposed to hot surfaces,
water pressure, or moving parts that
can cause serious injury or death!
Before performing any maintenance
or repair, disconnect spark plug
wire, let engine cool and release all
water pressure. The engine contains
flammable fuel. DO NOT smoke or
work near open flames while
performing maintenance.
To ensure efficient operation and
longer life of your pressure washer, a
routine maintenance schedule should
be prepared and followed. If the
pressure washer is used in unusual
conditions, such as high-temperatures
or dusty conditions, more frequent
maintenance checks will be required.
ENGINE
Consult the Engine Owners Manual for
the manufacturer's recommendations
for any and all maintenance. NOTE:
The frame is equipped with an oil drain
hole to help make changing the engine
oil easier.
PUMP
The oil in the high pressure pump was
designed to last the life of the pump. If
there is a problem with the pump
contact an Authorized Service Center.
NOZZLE CLEANING
If the nozzle becomes clogged with
foreign materials, such as dirt,
excessive pressure may develop. If
the nozzle becomes partially clogged
or restricted, the pump pressure will
pulsate. Clean the nozzle immediately
using the nozzle kit supplied and the
following instructions:
1. Shut off the pressure washer and
turn off the water supply.
2. Pull trigger on gun handle to
relieve any water pressure.
3. Disconnect the spray wand from
the gun.