Eastern Tools & Equipment IN2500i Portable Generator User Manual


 
ETQ
EASTERN TOOLS & EQUIPMENT INC Tele: (888)908-6200 Web Site: easterntools.com
9
(d) After checking, restart the engine. (d) After checking, restart the engine.
CAUTION: ───────────────────────────────────────────────────
z The generator AC output automatically resets when the engine is stopped and then restarted.
z The overload indicator light may come on for a few seconds at first when using electric devices
that require a large starting current, such as a compressor or a submergible pump. However,
this is not a malfunction.
───────────────────────────────────────────────────────────
3. DC APPLICATION (option)
This usage is applicable to 12V battery charging only.
(a) Charging instruction for battery
3
2
z Disconnect the leads for the battery.
z Make the battery fluid filler cap loose fully.
1
CSpecific gravity 20¡ ã
3. 47AH 20HR
2. 35AH 20HR
1. 30AH 20HR
Battery capacity
chargong time Hr
810
4
620
1.06
1.14
1.10
1.22
1.18
1.26
1.30
Aim for specific gravity and charging time
z Fill distilled water to the upper limit, if the battery fluid is
low level.
z Measure the specific gravity for the battery fluid by
using the hydrometer, and calculate the charging time in
according with the table shown on right side.
z The specific gravity for the fully charged battery shall be within 1.26 to 1.28. It is recommended
to confirm every an hour.
(b) Connect between the DC output socket and the battery terminals using the charging leads. The
leads shall be connected making sure of the (+) and (-) polarity.
(c) The DC circuit protector is to be set to “ON” after confirming the connection, if the protector is in
OFF” position.
CAUTION: ─────────────────────────────────────────────
z Be sure the “AUTO THROTTLE” switch is turned to “HIGH” while charging the battery.
──────────────────────────────────────────────────────