CARE AND MAINTENANCE
LUBRICATION:
A. Engine: Follow engine manufacturer's recommendation.
B. Deck spindles: Lubriacte with 3 "shots" only, every 100 hours.
C. Hydrostatic transmission and filter (follow instructions listed below).
Dirt or water in oil can ruin the hydrostatic transmissions.
Check the oil level in hydrostatic transmission oil reservoir after every 25 hours of usage. Clean
the oil reservoir cap and the area around it prior to removal. Check the oil level on the dipstick.
The proper oil level should register between the marked hole on the dipstick and the end of the
dipstick. Replenish as needed with 20W-50 Motor Oil. DO NOT OVERFILL. When checking
the oil level, be very careful to keep the reservoir clean.
Change the oil in the reservoir and hydrostat transmission oil filter after the first 100 hours of
use. Then every 500 hours after that. Remove the filter and be sure all oil has drained from the
reservoir. Replace with new filter and 20W-50 Mobil Super II.
CHECKING & REPLENISHING OIL IN HYDROSTATIC
TRANSMISSION
Please dispose of used oil at proper collection centers - protect your environment
Oil Reservoir Cap
Dipstick
Fuel Cap