DeWalt H1000IS Portable Generator User Manual


 
14- ENG
D28469
GROUNDING THE GENERATOR
A grounding lug is supplied with the generator for use
when required by local electrical ordinances. Refer to
article 250 of the National Electrical Code to clarify any
needed grounding information. Your local electric company
or a certified electrician should be able to help you with
this information.
Grounding Lug
BATTERY INSTALLATION
The generator is equipped with a maintenance free battery.
1. For packaging purposes the black
negative battery cable and battery
were secured with wire ties. Cut
these wire ties.
2. Connect black negative cable to
negative (-) battery post. Tighten
securely. NOTE: Make sure rubber
boot is covering positive (+) battery
terminal.
NOTE: If battery needs to be charged,
follow these instructions.
When charging the
battery, do not smoke.
Keep away from any sparks. The
fumes from the battery acid can cause
an explosion. To prevent explosive
fumes from accumulating do not
charge in an enclosed area.
Sulfuric acid is a
flammable and
explosive chemical that is harmful to
the skin, eyes, and clothing.
To prevent sparks,
disconnect the black
battery cable from the negative (-)
terminal before disconnecting the red positive cable.
1. Remove black negative battery cable from the battery.
2. Remove red positive battery cable from the battery.
3. Use a portable 12 volt battery charger, if needed, to bring battery to full
charge (12.6 at 70ºF.). Refer to the battery charger’s operator’s manual for
the correct procedure. If a battery charger is not available, have an
authorized service center charge the battery.
4. Connect the battery cables.
To Prevent sparks connect the red (positive) cable to the
positive (+) terminal before connecting the black negative
cable.
When transporting unit over extremely rough terrain by
vehicle the battery should be secured.
Negative Battery Cable
Wire Tie
Wire Tie
Negative Battery Cable
Positive
Battery Cable
with rubber
boot