Demco AC20037 Lawn Mower User Manual


 
Page 31
SPRAYER CHECKLIST:
Downtime caused by field breakdowns is costly and time consuming. Many breakdowns can be
eliminated by periodic equipment maintenance. By spending time reviewing this checklist before
seasonal spraying application time and following proper after season care, you can save time and
money later.
NOTE: DETHMERS MANUFACTURING COMPANY
does not and will not make any recommendations
concerning application of various chemicals or
solutions. These recommendations relate to either
amount or procedure of materials applied. If you
have any questions regarding application of certain
chemicals or solutions, contact your chemical
supplier and follow chemical manufacturer
recommendations.
Check Before Going To The Field :
1. NOZZLES
Check tip for excessive wear by checking for grooves in
or near tip opening. Check nozzle spacing by starting at
center and working outwards. Check boom for proper
height.
2. HOSES
Check all hoses for worn or soft spots. Be sure all hose
clamps are tightened and hoses are not kinked or pinched.
Check for leakage in any lines.
3. TANK
Remove and clean agitator orifices. Check orifices for
excessive wear by checking for grooves in or near orifice
opening. Inspect fitting and grommets to insure they are
in good condition.
4. CONTROLS
Check for leakage, plugging, or wear on all valves,
fittings, etc. Clean off any build up of foreign material.
5. PUMP
Check to be sure pump turns freely.
6. FRAME
Be sure all bolts are tightened.
7. REPLACEMENT PARTS
Replace all worn or damaged parts.
After Season Care:
NOTE: It is important to wear proper safety equipment
when cleaning the SIDEQUEST . See your
chemical or fertilizer package for this information.
1. After spraying chemicals, run water mixed with cleaners
through tank, pump and all hose hookups. If wettable
powder dries out in the system, it is very difficult to put
back into suspension and can cause malfunction,
damage or injury.
2. When cleaned, tank should have all openings closed or
covered to keep dirt from entering.
3. Pump should be flushed with soluble oil and pump ports
plugged to keep out moisture and air.
4. Disassemble tips and rinse with water or cleaning
solution. (Appropriate for chemical sprayed).
5. Clean tip opening with a wooden toothpick. Never use
wire or hard object that could distort opening.
6. Dispose of all unused chemicals or solutions in a proper
and ecologically sound manner.
6. Water rinse and dry tips before storing.
Keep hands, feet, and loose clothing away from rotating parts.
Wear protective clothing recommended by your chemical and
fertilizer manufacturer when working with chemicals.
WARNING: To Prevent Serious Injury Or Death!