17
caps and drain oil from both left and right
pumps. Replace and retighten nuts.
j. Coat new filter seal with oil before installa-
tion. Install new hydraulic oil filter filled with
new oil.
k. Add proper amount of hydraulic oil to res-
ervoir.
l. Run and purge gearboxes. Check oil level.
m. Add proper amount of hydraulic oil to res-
ervoir and repeat step L.
C.Electrical Circuit
Danger:
Read General Safety Precautions Nos. 9 and 10.
1. Battery: The battery is located beneath the
operator’s seat. To keep the outside of the
battery clean, brush on a strong solution of
bicarbonate of soda and water and rinse with
clean water. Keep the contacts and cable
ends clean with a wire brush and make sure
the connections are tight. Coat the terminals
with petroleum jelly to prevent corrosion.
2. Battery Storage: When storing the Mower for
long periods of time the following guidelines
should be taken.
a. Disconnect the battery cables from the ter-
minals and remove the battery. You will
have to remove the control panel to access
the battery strap. Replace control panel.
b. Clean the battery before storing. A dirty
battery will lose its charge over time.
c. Store the battery with a full charge. A dis-
charged battery will freeze (refer to the
table below).
d. Recharge battery when ever the specific
gravity value is less than 1.225
3. Battery Removal
Warning:
When removing the cables from the battery
follow these steps to avoid a short between
the wrench and the frame.
a. Remove the Negative (black) cable.
b. Remove the Positive (red) cable.
c. Release the hold down straps.
d. Remove the battery without tipping.
4. Installing the Battery
Note:
The battery is delivered from the fac-
tory fully charged and filled with electrolyte.
a. Attach the Positive (red) cable.
b. Attach the Negative (black) cable.
c. Attach the rubber battery strap.
5. Jump Starting
Warning:
Failure to use this starting procedure can
cause sparking, and the gases in the battery
to explode.
a. Attach the end of the red jumper cable to
the Positive terminal (+) of the charged
battery.
b. Attach the other end of the red jumper
cable to the Positive terminal (+) of the low
charge battery.
c. Attach the end of the black jumper cable to
the Negative terminal of the charged bat-
tery.
d. Attach the other end of the black jumper
cable to the frame of the unit with the low
charge battery.
6. Fuses: There is one fuse located in the wiring
between the ignition and start switch and
Figure. 8
Hydraulic pumps
Unfasten hose and drain from
this side of both pumps.
Specific Gravity Freezing Temp (°F)
1.265 -71
1.250 -62
1.200 -16
1.150 5
1.100 16