Cooper Lighting Envoy Landscape Lighting User Manual


 
EPL ENVOY
ORDERING INFORMATION
SAMPLE NUMBER: EPL-175-MP-MB-MT-TG-AP-L-EM/SC
BALLAST
MB=Magnetic
Ballast
3
EB=Electronic
Ballast
4
VOLTAGE
5
120=120V
208=208V
240=240V
277=277V
480=480V
DT=Dual-Tap w/277V
6
MT=Multi-Tap w/277V
6
TT=Triple-Tap w/347V
6
DISTRIBUTION
RD=Round
SQ=Square
TG=Rectangular
COLOR
[add as
suffix/must
specify]
AP=Grey
BK=Black
BZ=Bronze
WH=White
PRODUCT
FAMILY
EPL=Envoy
Parking
Luminaire
LAMP TYPE
MH=Metal Halide
MP=Pulse Start
Metal Halide
HPS=High
Pressure
Sodium
CF=Compact
Fluorescent
QL=Induction
LAMP WATTAGE
MH
1
175=175W
MP
2
70=70W
100=100W
150=150W
175=175W
200=200W
CF
84= [2] 42W
114= [2] 57W
126= [3] 42W
140= [2] 70W
168= [4] 42W
HPS
70=70W
100=100W
150=150W
Induction
85= 85W
OPTIONS
7
[add as suffix]
CD=Concentrated Downlight
[Restricts Uplight 360°]
8
CT=Conduit Taps [Qty [2] 3/4"
NPSM]
9
F=Single Fuse [Specify 120, 277
OR 347 in "Voltage" column]
FF=Double Fuse [Specify 208,
240 OR 480 in "Voltage"
column]
HA=40° C Ambient
10
HL=Hi/Low Dimming
11
L=Lamp Included, HID
LF=Lamp Included, Compact
Fluorescent
LQ=Lamp Included, Quartz
Halogen DCB
PH=Upper Polycarbonate Lens
[Near Aluminum Back
Housing]
PL=Lower Polycarbonate Lens
QD=Quick Disconnect[s]
[between cover/housing]
TMB=Trunnion Mount with
Connection Box [some
assembly required]
TMC=Trunnion Mount with
Power Cord [some
assembly required]
TR=Tamper Resistant [Torx T20
CPR]
WL=24” Lead Wires
STANDBY + EGRESS LAMP OPTIONS
Q=Quartz Restrike [hot restrike only, 120v T4 DCB quartz lamp]
12
EM=Quartz Time Delay [hot and cold restrike, 120v T4 DCB quartz lamp]
12
EM/SC=Emergency Separate Circuit [120v T4 DCB quartz lamp]
12
__CFSC=CF [1] Separate Circuit [Specify 52, 64 or 84, supplied with
120-277v electronic ballast]
13
__CFHR=CF Hot Restrike Relay [Specify 52, 64 or 84, supplied with
120-277v electronic ballast]
13
__CFTR=CF Time Delay Relay [Hot and Cold Restrike] [Specify 52, 64 or
84, supplied with 120-277v electronic ballast]
13
CFRB=CF Remote Battery Pack, sockets accommodate 26-42w CF lamps
[Battery Pack specified/supplied/wired by Others]
13
36CFIB=CF Integral Battery Pack operates [2] 18w CFL
14
CFRBT=CF Remote Battery Pack with Time Delay Relay, sockets
accommodate 26-42w CF lamps [Battery Pack
specified/supplied/wired by Others]
13
36CFIBT=CF Integral Battery Pack operates [2] 18w CFL with
Time Delay Relay
14
RBP=Remote Battery Pack, sockets accommodate 26-42w CF lamps
[CF units only; Battery Pack specified/supplied/wired by Others]
15
42IBP=Integral Battery Pack, [1] 42w CF lamp standby
16
42ICB=Integral Cold Weather Battery Pack, [1] 42w CF lamp standby
17
4CF3=4 CF lamps wired as 3 independent circuits, 3 electronic ballasts [2 lamps/1 lamp/1 lamp]
18
4CF2=4 CF lamps wired as 2 independent circuits, 2 electronic ballasts [2 lamps/2 lamps]
18
3CF2=3 CF lamps wired as 2 independent circuits, 2 electronic ballasts [2 lamps/1 lamp]
19
2CF2=2 CF lamps wired as 2 independent circuits, 2 electronic ballasts [1 lamp/1 lamp]
20
TL__=Task Light 120v MR16 [GU10 Twist Lock Base]
21
2TL__=[2] Task Lights 120v MR16 [GU10 Twist Lock Base]
21
TLQ__=Task Light 120v MR16 wired to Hot Restrike Relay [GU10 Twist Lock Base]
22
2TLQ__=[2] Task Lights 120v MR16 wired to Hot Restrike Relay [GU10 Twist Lock Base]
22
TLEM__=Task Light, 120v MR16 wired to Time Delay Relay [GU10 Twist Lock Base]
22
2TLEM__=[2] Task Lights, 120v MR16 wired to Time Delay Relay [GU10 Twist Lock Base]
22
TL12V__=Task Light, 12v MR16 [GU5.3 Bi-Pin Base]
23
2TL12V__= [2] Task Lights, 12v MR16 [GU5.3 Bi-Pin Base]
23
TL__MR__=Task light with transformer [GU5.3 Bi-Pin Base, specify 50 or 75w lamp,
specify 120 or 277v transformer]
24
OPTIONS + ACCESSORIES [Must be listed in the order shown and separated by a dash]
DIMENSIONS
STANDARD COLORS
NOTES: 1 Metal Halide lamps with probe start circuit. 2 Pulse Start Metal Halide circuit includes igniter. 3 HID lamps only. 4 Must specify voltage. EB standard on CF. Available integrally in HID 100w MP [max] and
85w QL. HID availability may vary by lamp source, wattage and voltage. For HID wattages higher than 100w, remote mount ballast possible within 5 feet of unit. Consult customer service. 5 Product also
available in non-US voltages and 50Hz for international markets. Must specify voltages for battery packs. Consult your customer service representative for availability and ordering information. 6 Dual tap
ballast is 120/277V wired 277V. Multi-tap ballast is 120/208/240/277V wired 277V. Triple tap ballast is 120/277/347 wired 347V. 7 Add as suffix in order shown. 8 Requires option PL for use in 40°C
application with HID lamps 175-200w. 9 CT option required for through branch wiring. Through branch wiring is not available with specific configurations including HID CF egress options and fixtures
with integral battery pack. 10 Not available with 85w QL and options using CF lamp sources. Requires option PH on 200-175w HID. 11 Available in 150-200w MP, 175w MH and 70-150w HPS. Operates
on 24VDC type output control module. Circuit relay board is mounted internal to fixture housing with leads exiting back. Requires low voltage wires to control module to be routed in conduit. 12 For use
with HID primary lamp only. Quartz lamp 100w maximum. 13 For use with 175w [max] or less HID primary lamp only. Requires option “CT”. Uses [2] 4 pin CF lamps. CF minimum starting temperature 0°F
[-18°C]. RB requires “CT”option 14 For use with 150w [max] or less HID primary lamp only. Uses [2] 18w 4 pin CF lamps. Battery rated minimum 32°F/ 0°C. Specify 120 or 277v in "VOLTAGE" column. 15
For use with 168, 126, 84 CF units only. Requires option “CT”. Battery supplied by others. Standby lamp combination wired by others. 16 For use with 168, 126, 84 CF units only. Battery rated minimum
32°F/ 0°C. Specify 120 or 277v in "VOLTAGE" column. 17 For use with 168, 126, 84 CF units only. Battery rated minimum -4°F/ -20°C. Specify 120 or 277v in "VOLTAGE" column. 18 For use with 168 CF
only. 19 For use with 126 CF only. 20 For use with 84, 114, or 140 CF only. 21 Task Light[s] with separate leads through back of fixture. Specify TL location by adding to back of option logic
[ex.2TLA1A2]-see diagram. Some assembly required, order lamps separately. 22 For use with HID lamps only. Task Light[s] supplied wired to relay. Specify TL location by adding to back of option logic
[ex.2TLA1A2]-see diagram. Some assembly required, order lamps separately. 23 Task Light[s] supplied with separate leads through back of fixture for connection to 12v circuit or battery system. Specify
TL location by adding to back of option logic [ex.2TLA1A2]-see diagram. Some assembly required, order lamps separately. 24 Task Light max quantity [1], supplied with transformer. Specify TL location
by adding to back of option logic [ex.2TLA1A2]-see diagram. Some assembly required, order lamps separately. 25 Order separately, replace XX with color suffix 26 Luminaire requires option WL. 27 Order
additional shield set for more coverage [ex. 2 sets for 180° shielding] Maximum of 2 sets total. 28 Placed towards side of oncoming traffic for 60° shielding coverage. Order [2] for 2-Way traffic lanes. 29
Some options and accessories are not available in all configurations. Consult your customer service representative for ordering information. 30 Specifications and dimensions subject to change without
notice.
ACCESSORIES
25
[order separately/
replace XX with color designation]
OPTIONS +
ACCESSORIES
[See Below]
AP
Grey
WH
White
BK
Black
BZ
Bronze
16 3/8 (415mm)
13 1/2
(334mm)
LAMP TYPE WATTAGE
Metal Halide
175W
High Pressure Sodium 70, 100, 150W
Pulse Start Metal Halide 70, 100, 150, 175, 200W
Compact Fluorescent [2] 42, [2] 57, [3] 42, [2] 70, [4] 42W
Induction 85W
CERTIFICATIONS
IP66 Rated
40°C Ambient Temperature*
C-UL/U.L. 1598 Listed Wet Location
2G Vibration Tested
ISO 9001
WATTAGE TABLE
SHIPPING DATA
NOTE: * Varies by model.
EPL/PBG-XX=Balanced Pendant
Box/Bird Guard
EPL/WM-XX=Wall Mount Arm
26
EPL/HS=House Side Shield Up and
Downlight 120° Coverage [HID
Lamps Only]
27
EPL/HSCF=House Side Shield Up and
Downlight 120° Coverage
[CF Lamps Only]
27
EPL/DLS=Drive Lane Shield
28
VRSD=T20 Torx CPR Tamper Resistant
Screwdriver
EPL/TL=Task Light Field Install Kit for
120V MR16 lamp [GU10 Base]
EPL/TL12V=Task Light Field Install Kit for
12V MR16 lamp [GU5.3 Base]
Net Weight [21 lbs.]
Volume [2.1 cu. ft.]