SKU 92146 For technical questions, please call 1-800-444-3353. PAGE 9
6. If you are using an extension cord outdoors, make sure it is marked with the suffix
“W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.
7. Make sure your extension cord is properly wired and in good electrical condition.
Always replace a damaged extension cord or have it repaired by a qualified
electrician before using it.
8. Protect your extension cords from sharp objects, excessive heat, and damp or wet
areas.
9. If an extension cord is needed, only use a cord with the proper gauge wire.
(See Figure B.)
SYMBOLOGY
FIGURE B
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*
(120 VOLT)
NAMEPLATE
AMPERES
(At Full Load)
EXTENSION CORD LENGTH
25
FEET
50
FEET
75
FEET
100
FEET
150
FEET
0-2.0
18 18 18 18 16
2.1-3.4
18 18 18 16 14
3.5-5.0
18 18 16 14 12
5.1-7.0
18 16 14 12 12
7.1-12.0
16 14 12 10 -
12.1-16.0
14 12 10 - -
16.1-20.0
12 10 - - -
*Based on limiting the line voltage drop
to five volts at 150% of the rated amperes.
WARNING: NEVER use 16 or 18 gauge extension cords
of any length on this Pressure Washer.