Chauvet 350 Landscape Lighting User Manual


 
Page 18 of 26 Intimidator™ Spot LED 350 User Manual (Rev. 02)
Miscellaneous Operations
Reset Software
To reset the software on the Intimidator™ Spot LED 350, do the following:
1. Press <MODE/ESC> repeatedly until rESt shows on the display.
2. Press <ENTER>. The product will reset all settings in the software to the default
factory settings.
Password
Channel
The Intimidator™ Spot LED 350 contains a password-protected mode which allows you
to calibrate and troubleshoot any small issues you may have during normal operation.
In order to access this mode, do the following:
1. Press and hold <MODE/ESC> for at least 10 seconds.
2. Use the <UP> and <DOWN> buttons to enter the password: 2323.
3. Press <ENTER>.
In this mode you have several options for adjustment.
Parameter
Programming Steps
Description
Pan Adjust
P128
Manually adjust the pan angle
Tilt Adjust
t128
Manually adjust the tilt angle
Gobo Wheel Adjust
G128
Manually adjust the gobo wheel
Color Wheel Adjust
C128
Manually adjust the color wheel
Focus Adjust
F128
Manually adjust the focus
Prism Adjust
L000
Manually adjust the prism
Lamp Brightness Adjust
d000
Manually adjust the starting
brightness of the lamp