3. SETUP
AC Power
This product has a fixed voltage power supply and
can work with an input voltage of
either 120 V, 60 Hz or 230 V, 50 Hz, depending on the specific model.
To determine the power requirements for this product
(circuit breaker, power outlet, and
wiring), use the current value listed on the label affixed to the product’s back panel, or
see the Technical Specifications. The listed current rating indicates the product’s
average current draw under normal conditions.
Always connect this product to a protected circuit
(circuit breaker or fuse),
making sure that it has
an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect this product to
a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0~100% switch.
Resetting the
Breaker
This product uses a resettable circuit breaker. Follow the instructions below to reset.
Disconnect this product from the power outlet before resetting the breaker.
This product is equipped with a resettable circuit breaker on the power input circuit.
1. Remove the power cord from the power outlet.
2. Allow unit to cool for 15 minutes.
3. After 15 minutes, you may attempt to reset the breaker by pressing the button with
your index finger until it latches in the operation position.
4. Plug the product’s power cord into the power outlet and continue using as
recommended.
If the breaker does not reset (the breaker button will not remain inserted), contact
CHAUVET® immediately, as this indicates a possible internal malfunction.