• DEC Switch - This is the declination switch error value set when Utilities / Calibrate Mount /
DEC Switch - Cone is carried out.
• RA Switch - This is the R.A. switch error value set when Utilities / Calibrate Mount / R.A.
Switch is carried out.
Utility Features
Scrolling through the MENU (9) options will also provide access to several advanced utility functions within
the CGE such as; Mount Calibration, Periodic Error Correction, Hibernate as well as many others.
Calibrate Mount - In order to optimize the performance and pointing accuracy of
the CGE mount, the CGE has built-in calibration routines allowing it to compensate
for mechanical variation inherent in every German equatorial mount. Each
calibration is completely automatic and in most cases only needs to be performed
once. It is highly recommended that you take a few minutes to go through the mount
calibration procedures.
• Dec Switch / Cone Calibration – this procedure simultaneously
records the offset error when the declination switch is found at start-up
and compensates for "cone" error due to slight misalignments of the
optical tube and declination axis. For more information on calibrating
the Dec switch and cone error, see the box called "Calibrating the
CGE Mount" in the Startup Procedure section earlier in this chapter.
• R.A. Switch Calibration - this procedure records the offset error when
the right ascension switch is found at start-up. Calibrating the R.A.
switch will improve the accuracy of your initial star alignments when
aligning the telescope.
• GoTo Calibration – Goto Calibration is a useful tool when attaching
heavy visual or photographic accessories to the telescope. Goto
Calibration calculates the amount of distance and time it takes for the
mount to complete its final slow goto when slewing to an object.
Changing the balance of the telescope can prolong the time it takes to
complete the final slew. Goto Calibration takes into account any slight
imbalances and changes the final goto distance to compensate.
Move to Switch –
Slews the telescope to locate either its R.A. or declination
switches.
Home Position –
The telescopes "home" position is a user-definable position that is used to store the telescope
when not in use. The home position is useful when storing the CGE telescope in a permanent observatory
facility and especially when using the Hibernate feature to maintain a star align over many observing sessions.
Polar Align- The CGE has a polar alignment function that will help you polar align your telescope for
increased tracking precision and astrophotography. After performing an Auto Two-Star Alignment, the
telescope will slew to where Polaris should be. By using the equatorial head to center Polaris in the eyepiece,
the mount will then be pointed towards the actual North Celestial Pole. Once Polar Align is complete, you must
re-align your telescope again using any of the alignment methods described earlier. To polar align the CGE
mount in the Northern Hemisphere:
DEC SWITCH / CONE
R.A. SWITCH
GOTO
CALIBRATE MOUNT
R.A. TO SWITCH
DEC TO SWITCH
MOVE TO SWITCH
GOTO
SET
HOME POSTION
POLAR ALIGN
PLAYBAC
K
RECORD
PEC
LIGHT CONTROL
PRESS UNDO
PRESS "0"
FACTORY SETTING
VERSION
GET ALT-AZ
GOTO ATL-AZ
HIBERNATE
TURN ON/OFF RTC
TURN ON/OFF GPS
UTILITIES