CIRCUIT BREAKER
(TRIP BREAKER FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
FUSE BOX
(REMOVE FUSE FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
The blades in each pack are matched for
equal weight to assure smooth fan operation.
If more than one fan is being installed, be
careful not to mix blades from different
cartons.
Inspect the contents of your carton for
possible shipping or handling damage. If
parts are missing or damaged, call 1-888-
227-2178.
It is always a good idea to have an assistant
to help with the installation.
When cleaning, painting, or working near
your fan, be very careful of the fan and
blades. Always turn the power OFF to the
ceiling fan before servicing it, working on
it, or replacing lightbulbs.
Never insert anything into the path of the
fan blades while the fan is in operation.
Never install a fan over a pool or spa.
Never operate a fan that has been damaged in
any way. Contact Casablanca Fan Company by
calling 1-888-227-2178, or contact your local
Authorized Casablanca Dealer for assistance
in obtaining service.
CONTENTS
READ AND SAVE THESE INSTRUCTIONS
All wiring must be in accordance with the National Electric Code ANSI/NFPA 70-1993 and the appropriate local electrical
codes. The National Electric Code requires proper grounding as a precaution against electrical shock. A qualifi ed electri-
cian should be consulted if you are unsure.
This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling
fan installations. If it is not, a new box must be installed. Casablanca extension poles are available for sloped or high
ceiling installations.
This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15-amp circuit. The maximum
current requirement for the fan with light fi xture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light
current is 0.83 amps (100 watts) of lighting.
Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy hatch, make
sure all wires are within the canopy and that no wires are being pinched.
The fan must be supplied with 3 independent 120V AC supply wires to provide power for the fan, the light, and neutral.
For best performance and for your warranty to be valid,
use only genuine Casablanca blades, light fi xtures, and accessories.
SAFE USE
Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product
and proper installation; therefore, before attempting to install and operate your Casablanca fan, read this
owner’s manual completely and carefully. Retain this manual for future reference.
SAFETY FIRST
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PREPARATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FAN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CONTROL FEATURES:
W-1811 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
BEFORE YOU START
P/N 6543010 REV. F P/D AT0208
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off at
the circuit breaker or fuse box before attempting any installation procedure.
18"
84"
FROM BOTTOM
EDGE OF BLADE
TO FLOOR
DIMENTIONS INDICATED ARE THE
MINIMUM ALLOWABLE FOR PROPER
INSTALLATION