Casablanca Fan Company 46UXXD/M Outdoor Ceiling Fan User Manual


 
11
3-SPEED W-80 WALL CONTROL OF THE FAN & LIGHT(S)
3-SPEED W-40 WALL CONTROL OF THE FAN
•The fan may be turned ON and OFF
by the W-80 wall control.
•The lights may be turned ON and
OFF by the W-80 and the inten-
sity adjusted from low to high.
•The fan must be supplied with two
independent 120V AC supply
wires.
Set the FAN pull chain switch to
the HIGH speed setting.
•Turn the lights ON at the fan.
•The W-80 allows the choice of four
(4) different speed settings.
•The W-40 allows the choice of four
(4) different speed settings.
•No light fixture is used.
Set the FAN pull chain switch to the
HIGH speed setting.
•No changes in household or fan wiring
are required.
•The fan may be turned ON and OFF by
the W-40 wall control.
CAUTION! Failure to set the pull-chain
speed to HIGH can result in faulty
operation of the fan and damage to
the W-40 wall control. To confirm fan
is set to HIGH: Turn W-40 fan speed
switch to 'HI' - set fastest fan speed
with pull chain.
CAUTION! Failure to set the pull-
chain speed to HIGH can result in
faulty operation of the fan and
damage to the W-80 wall control.
To confirm fan is set to HIGH: Turn
W-80 fan speed switch to 'HI' -
set fastest fan speed with pull
chain.
R