System Connection
1. Insert lance into the gun and turn
clockwise to positive stop as shown
in Figure 5.
2. Be sure that the power switch is in
the “OFF” position.
3. Attach the high pressure hose onto
the pump water outlet by turning
clockwise and hand tightening. Be
certain to push hose onto pump
while tightening. Be careful to not
cross thread the hose.
4. Connect garden hose as explained
under Garden Hose Connection
Instructions.
5. Plug the power cord into a
grounded 120V outlet.
6. Turn water on.
7. Unlock trigger lock by moving lock
right to left.
8. Depress and hold the trigger on
the gun for one minute to release
pressure and remove any air trapped
in the system.
9. Turn the “ON/OFF” switch to the
“ON” position, while pulling the
trigger.
Operating Instructions and Parts List PW1350
Figure 5 - Gun/Lance Connection
ON OFF
Figure 6 - ON/OFF Switch
How to Avoic Damaging
Surfaces
Directions for Use
Damage to cleaning surfaces occurs
because the impact force of the water
exceeds the durability of the surface. You
can vary the impact force by controlling
the nozzle’s fan pattern, the nozzle’s
angle to the cleaning surface, and the
nozzle’s distance from the cleaning
surface. Never use a narrow high impact
stream or a turbo nozzle on a surface
that is susceptible to damage. Avoid
spraying windows with a narrow high
impact stream or turbo nozzle. Doing so
may break the window. The surest way
to avoid damaging surfaces is to follow
these steps:
1. Before triggering the gun, adjust
the nozzle to a wide fan pattern.
2. Placethenozzleapproximately4-5
feet away from the cleaning surface.
Then hold the nozzle at a 45° angle
to the cleaning surface. Trigger the
gun.
3. Vary the fan pattern spray angle and
the distance to the cleaning surface
until optimum cleaning efficiency
is achieved without damaging the
surface.
Nozzle Cleaning Instruction
A clogged or partially clogged nozzle can
cause a significant reduction of water
coming out of the nozzle and cause the
unit to pulsate while spraying.
To clean out the nozzle:
• Turnoffunit.
• Turnoffwatersupply.Relieveany
pressure trapped in the hose by
squeezingtrigger2-3times.