Blue Rhino 200209-450000 Patio Heater User Manual


 
Replacing Control Valves Series 200209 – 450000 LP Gas 404121 1
®
For assistance call 1.800.762.1142.
Replacing Control Valves Series 200209 – 450000 LP Gas 404121 2
®
For assistance call 1.800.762.1142.
Tools required:
• # 2 Phillips screw driver
• 8mm open end wrench
• 9mm open end wrench
• 10mm open end wrench
• 12mm open end wrench
• 5/8” open end wrench
• 3/4” open end wrench
• 7/16” nut driver or wrench (series 235000-450000)
• Locking pliers
• Leak test solution
• Ratchet
• 9/16” socket
• Extension 7.5” in length
• Penetrating oil
• Leak test solution 1 part liquid soap and 3 parts water.
1. Installation and repair should be done by a qualified service person.
2. Use only Blue Rhino Global Sourcing, LLC. factory authorized parts. The use of any part
that is not factory authorized can be dangerous. This will also void your warranty.
Contact 1.800.762.1142.
DANGERS and Cautions