Blue Rhino 200209-450000 Patio Heater User Manual


 
Replacing Control Valves Series 200209 – 450000 LP Gas 404121 15
®
For assistance call 1.800.762.1142.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three
parts water.
2. Make sure control knobs are off.
3. Turn LP gas tank ON at valve.
4. Spoon leak check solution at all “x” locations
5. If any bubbles appear turn LP gas tank OFF, reconnect and re-test. If you continue to see
bubbles after several attempts, disconnect LP gas source and contact 1.800.762.1142 for
assistance.
6. If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.
Pilot, Pilot Supply Tube and Burner Supply Tube
1. Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts
water.
2. Turn LP gas tank ON at valve.
3. Turn control knob on to LOW
4. Remove access panel
5. Place leak solution on pilot supply tube at the pilot and at the control valve.
6. Place leak solution on the burner supply tube.
7. If any bubbles appear turn control valve OFF, check all connection to make sure they are
tight, and retest. If you continue to see bubbles after several attempts, turn control valve off
and disconnect LP gas source and contact 1.800.762.1142 for assistance.
8. If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.
X
X
X
X
X