MAINTENANCE SCHEDULE
The chart below shows the recommended
maintenance schedule that should be
performed on a regular basis. More frequent
service may be required.
* After rst two hours of operation.
CHECK DUAL HANDLE
INTERLOCK
Without the engine running, press down
(engage) both clutch levers. Release
attachment clutch lever. Attachment clutch
should remain engaged until traction clutch
lever is released, then both clutches must
disengage.
CHECK FASTENERS
Make sure all hardware is tightened properly.
CHECK CLUTCHES
Auger / impeller must stop within 5 seconds
when attachment clutch/impeller brake lever is
released.
Wheels must stop quickly when traction drive
clutch lever is released.
If clutches do not engage or disengage
properly, adjust or repair before operation (see
Service and Adjustments).
CLEAN ENGINE
Refer to Engine Manual for detailed
instructions.
CHECK ENGINE OIL
The engine crankcase oil should be checked
every 5 hours of operation. Oil level MUST be
maintained in safe operating range on dipstick
at all times or engine damage will result (See
Engine Manual).
Park unit on a level surface. Refer to Engine
Manual for detailed instructions.
CHANGE ENGINE OIL
Change oil after rst 2 hours of operation,
thereafter change oil every 25 hours (more
often if required). Refer to Engine Manual for
detailed instructions.
Run engine just prior to changing oil. Warm oil
will ow more freely and carry away more
contamination.
CHECK TIRE PRESSURE
Keep tires at pressure listed on the tire
sidewall.
CHECK AUGER GEARCASE
IMPORTANT: Proper oil level must be
maintained.
Gear cases are lled to the correct level at the
factory. Unless there is evidence of leakage,
no additional lubricant should be required.
Check oil level each season or every 25 hours
of operation.
To ensure adequate lubricant level:
1. Remove ller plug (Figure 10). Lubricant
must be at least up to bottom of lubricant
ller hole with unit resting on a
level-surface.
2. Add lubricant if required. Allow oil to drain
to level of plug and replace plug.
IMPORTANT: Use only Ariens special gear
lubricant L-2 (Part Number 00008000).
MAINTENANCE SCHEDULE
Service
Performed
Each
Use
Every
5 hrs.
Every
25
hrs.
Yearly
Check Dual
Handle
Interlock
Check
Fasteners
Check
Clutches
Clean Engine
Check Engine
Oil
Change
Engine Oil
*
Check Tire
Pressure
Check Auger
Gearcase
••
General
Lubrication
••
Battery