14
754323-100 Rev A
All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.
WARNING: When using electrical products, basic precautions should always be observed, including the following:
1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.
2. Grounding is required. The unit should be installed by a licensed electrician and grounded.
3. Permit access for servicing motor as noted.
4. All building materials and wiring should be routed away from the pump body and heater (if equipped).
ELECTRICAL INSTALLATION INSTRUCTIONS
This installation requires 3 separate 120VAC dedicated circuits with GFCI (Ground Fault Circuit Interrupter) protection as
shown in Figure 2. Two of the three GFCI outlets MUST be 20AMP service.
At initial start-up with the power ON, push the GFCI test button. The reset button should pop out. Push this button in to reset.
If the GFCI fails to operate in the manner, there is a ground fault or malfunction, indicating the possibility of electrical shock.
Turn off the power and do not use until the source of the problem has been identified and corrected.
FIGURE 2: ELECTRICAL INSTALLATION DIAGRAM
!
BLACK
WHITE
120 VAC
GND.
BLACK
WHITE
120 VAC
GND.
BLACK
WHITE
120 VAC
GND.
20A GFCI OUTLET 20A GFCI OUTLET 15A GFCI OUTLET
“WHIRLPOOL WITH 2 LIGHTS”
CONFIGURATION
“AIR BATH”
CONFIGURATION
WHIRLPOOL TEE HEATER
POWER
DISTRIBUTION
BOX
AIR BLOWER
120V @ 10A MAX
WHIRLPOOL PUMP
120V @ 15A MAX
2 LIGHTS
120V @ 1A
WHIRLPOOL HEATER
120V @ 13A MAX