American Standard American Standard bath Hot Tub User Manual


 
10
754323-100 Rev A
C/L
FOR SPOUT
& VALVES
FOR HAND
SPRAY
FITTINGS
DECK
EDGE OF
FITTINGS
DECK
35-3/4
(908mm)
TO END OF TUB
1-1/2
(38mm)
1-1/2
(38mm)
1-1/2
(38mm)
2-1/2
(64mm)
4-1/2
(114mm)
4-1/2
(114mm)
5
(127mm)
DRAIN
HOLE DRILLING LOCATION FOR AMERICAN STANDARD "TOWN SQUARE"
DECK MOUNT BATH FILLER WITH PERSONAL SHOWER, MODEL #2555.901 ONLY
CONTROL
PANELS
41-3/4"
(1060mm)
26-3/4
(679mm)
7-3/4” TYPICAL
(197mm)
OUTLINE OF SKID
RESISTANT SURFACE
35-3/4"
(908mm)
13-1/4"
(337mm)
71-1/2"
(1816mm)
3"
(76mm)
FLOOR CUTOUT
9" X 19"
(229 X 459mm)
OUTLINE OF CUTOUT
70" X 40-1/4" (1778 X 1022mm)
INTEGRAL
FITTING DECK
2-1/4" X 14"
(57 X 356mm)
3/4"
(19mm)
EDGE OF
FLOOR
CUTOUT
AIR
BLOWER
20 AIR
JETS
LEVELING STRINGER
(NOT FOR SUPPORT)
2"
(51mm)
3-1/4"
(83mm)
20"
(508mm)
22"
(559mm)
ROUGH
FLOOR
10-1/4”
(260mm)
INTEGRAL FEET WITH
ATTACHED BASEBOARD
8 WHIRLPOOL
JETS
ACCESS AIR BLOWER, PUMP
MOTOR, WHIRLPOOL HEATER
AND LIGHTING SYSTEM AT
THIS END OF TUB
NOTE:
INSTALLER MUST PROVIDE 12 X 24 ACCESS OPENING FOR SERVICING AIR
BLOWER, PUMP MOTOR, WHIRLPOOL HEATER, AND LIGHTING SYSTEM.
THIS MODEL INCLUDES A DRAIN ASSEMBLY. OTHER DRAIN ASSEMBLIES
CANNOT BE USED. REVIEW DRAIN INSTALLATION DETAILS IN THE DOCUMENT
TO FULLY UNDERSTAND FLOOR CUTOUT REQUIREMENTS.
TOP VIEW
END VIEW
TOWN SQUARE
®
6' x 42"
MODEL 2742 COMBINATION SYSTEM
ROUGHING-IN REFERENCES