Aigo PB2200 Outdoor Fountain User Manual


 
Part 11
USING THE PB SYSTEM
BEFORE POWER ONA Check List
It is very important that you check the following operational points:
Ventilation
This terminal must NOT be operated in an environment with
restricted ventilation. There must be at least 25 mm air clearance around any
top or side ventilation holes with a free flow of air around the unit at ALL
times for the installation.
Operating Environment
The equipment must not site in direct sunshine, near a heater or in a
damp area and must be free from contaminants like dust, smoke or fume.
The equipment must not be operated or stored in extremes of both
temperature and humidity/moisture.
(Operating range 0°C to + 35°C and up to 80% relative humidity –
non condensing max. wet bulb 26°C)
Power Supply
The operating voltage of the power supply should be checked to
confirm that it is set within the range of the local power supply. The power
cable, the power outlet and any power fusing arrangements must conform to
local safety regulations.
UPS Battery (option)
General care:
The UPS battery is consumable beyond product warranty. Please
definitely observe the alerts in beginning of this manual. If the equipment is to
be powered off for more than few days, please always disconnect the battery
from the system. Reconnect it and turn on the system to recharge the battery
for 1 ~ 2 hours every 3 months for temperature lower than 30°C. Recharge for
1 ~ 2 hours every month for temperature over 30°C. Temperature above 40°C
must be strictly avoided as it could cause termination of battery life and
unexpected result even if the battery is not in work. The UPS battery can
support basically the data preservation and smooth running of the system
during intermittent or few minutes (3 ~ 20 min. depending on loading and
battery condition) power failure.
Battery replacement:
In the preloaded OS for a PB-2200 Pro series, there is a built in
utility Posiflex Power Switch Manager that will
indicate the UPS battery status of the battery. When
an installed UPS battery is found to be disabled or
when pop up warning message like this picture