Agri-Fab 45-02103-101 Spreader User Manual


 
7
FIGURE 12
22. Place the adjustable stop into the "ON" end of the
slot in the top of the flow control mounting bracket.
Secure with the 1/4" x 3/4" carriage bolt, a nylon
washer, a 5/16" flat washer and the nylon wing nut.
See figure 12.
23. Position the flow control mounting bracket (figure
13).
a. Push on flow control arm until it locks in "OFF"
position.
b. Slide flow control mounting bracket along tube
until closure plate in bottom of hopper just closes.
c. Snug the 1/4" lock nuts just enough to hold flow
control mounting bracket in place.
d. Set adjustable stop at "5". Pull flow control arm
against stop. Verify that closure plate has opened
about half way.
e. If closure plate does not open half way, it may be
closed too far at "OFF". Adjust position of flow
control mounting bracket until closure plate will
open about half way at "5" and still close when
arm is locked in "OFF". Tighten 1/4" lock nuts.
5/16" FLAT
WASHER
NYLON
WASHER
1/4" x 3/4"
CARRIAGE BOLT
NYLON
WING NUT
ADJUSTABLE
STOP
OFF
ON
1
2
3
4
6
7
8
9
10
5
FLOW
CONTROL
ARM
ON
OFF
AJDUSTABLE
STOP
SETTING "5"
FIGURE 13