Troubleshooting
To view a fault list:
1. On the Select Device menu, highlight System and press Enter.
2. On the System Settings menu, highlight View Fault List.
3. Press Enter.
Warning Types
There are two types of warnings: automatic and manual. When the Freedom
SW detects a warning condition, it displays a warning message on the SCP.
Table 3 describes how they differ in their behavior and in how you can
respond to them when they appear on the SCP.
To view a warning list:
1. On the Select Device menu, highlight System and press Enter.
2. On the System Settings menu, highlight View Warning List.
3. Press Enter.
Escalating automatic
faults
Clear automatically if the fault condition goes
away, just like an automatic fault.
However, if an escalating automatic fault
occurs several times within a defined time
period, the escalating automatic fault becomes a
manual fault, requiring user intervention. For
example, if three faults occur in one minute, it
will no longer clear itself but becomes a manual
fault. Then you must identify the problem,
correct the fault condition, and clear the fault or
reset the device.
Table 2
Faults Types and Behaviors
Fault type Behavior
Table 3
Warning Types and Behavior
Warning type Behavior
Automatic warning Clears automatically if the fault condition that
generated the message goes away. You can also
acknowledge automatic warnings without
waiting for them to clear automatically.
Manual warning Requires you to acknowledge it before you can
proceed with configuring or operating the
Freedom SW. Manual warnings are usually in
the form of a
Yes/No question that you may acknowledge by
pressing the Enter button on the SCP for Yes
and the Func button for No.
Refer to the Xanbus System Control Panel
Owner’s Guide for more information.