2. OUTDOOR UNIT INSTALLATION
2-1. INSTALLING THE UNIT
• Besuretoxtheunit’slegswithboltswheninstallingit.
• Besuretoinstalltheunitrmlytoensurethatitdoesnotfallbyanearthquakeoragust.
• Refertothegureintherightforconcretefoundation.
• Do not use the drain socket and the drain cap in the cold region.
Drainmayfreezeanditmakesthefanstop.
Fix here with
M10 bolts.
Make the setting
depth deeper.
Make with wider.
Anchor leg
25(1)orless
Anchor both length
Anchor both pitch
[Unit:mm(inch)]
2-2. CONNECTING WIRES FOR OUTDOOR UNIT
• Be sure to use special circuits for room air conditioner.
• Wiring work should be based on applicable technical standards.
• Wiring connections should be made following the diagram.
• Screwsshouldbetightenedsotheywon’tloosen.
ELECTRICAL SPECIFICATIONS
INDOOR UNIT
MSZ-A09NA MSZ-A12NA MSZ-A15NA MSZ-A17NA MSZ-A24NA
Power
supply
(V,PHASE,Hz) 208/230, 1, 60
Min.CircuitAmpacity(A)
1.0 1.0 1.0 1.0 1.0
Fanmotor
(F.L.A) 0.76 0.76 0.76 0.76 0.76
OUTDOOR UNIT MXZ-3A30NA MXZ-4A36NA
Powersupply
(V,PHASE,Hz) 208/230, 1, 60
Max.Fusesize(timedelay)(A)
20 20
Min.Circuit
Ampacity(A) 15 19
Fanmotor
(F.L.A) 0.93 0.93
Compressor
(R.L.A) 11 14.4
(L.R.A) 15 15
Control voltage
Indoor
unit-Remotecontroller:(Wireless)
Indoor unit-Outdoor unit : DC12-24V
Terminalblockforpowersupply
Service panel
500
(19.69)
330
(13.00)
1)Removetheservicepanel.
2)Fixtheconduitconnectortoconduitcoverwithlocknutthensecureit
against unit with screws.
3)Fixtheconduitcovertotheoutdoorunitthensecureitwithscrews.
4)Connectpowersupplyandindoor/outdoorconnectingwiretotheterminal
block.
(Leave
someslackinwirestoalloweasierservicing.)
5)Closetheservicepanelsecurely.Makesurethat3-2.PIPECONNECTION
is completed.
Connecting order
• Connect the terminal block in order,
from the A, B and C unit side.
Powersupply
Terminal block for
indoor/outdoor unit
4A36NA
SG79Y871H02.indb 5 9/7/2007 1:09:40 PM