14
3.2 System design and installation 3. Installation
Step 5
The pump will not be supplied pre-filled with oil therefore this
table must be used to select recommended oil.
Oil changing: Oil level must be checked with the pump static.
First change: After 150 hours of operation, thereafter every
3000 hours of operation.
Oil filling: Fill with oil through the filler plug to the level indicated
in the sight glass.
NOTE!
On horizontally ported pumps the sight glass must be fitted to
the upper hole on the side of the gearcase.
Refer to technical data (chapter 5) for oil quantities required.
Pump Operating Temperature
-20°C to +130°C +130
o
C to 200°C
(-4°F to +266°F (+266°F to 392°F)
BP Energol GR - XP150 BP GRS15
Castrol Alpha SP150 Castrol Alpha SN150
Mobil Gear 629 Mobil Glycoyle 30
Shell Omala 150 Shell Tivela WA
Texaco Meropa 150 Texaco Synlube SAE90
Esso Spartan EP150 Esso IL1947