A SERVICE OF

logo

Transmission Fluid Exchanger
99
99
9
Operating Procedures
e. The volume of new fluid yet to be pumped
into the transmission pan is shown on
New
Fluid In
display (the amount designated in
“Power Up” step 10 minus the amount
transferred in “Start Service” step 1d).
f. The
Start Engine
and ENTER LEDs flash.
2. Start the vehicles engine to circulate the
ATF through the transmission system (torque
converter and cooler lines).
3. Press ENTER to confirm the engine is
running.
The unit extracts used ATF from the cooler lines
and returns new ATF through the nylon transfer
hose and back into the transmission fluid pan.
The
Replace Fluid Out
and
New Fluid In
displays respectively the amount of ATF
extracted and the amount of new ATF added.
This recycling continues until the selection made
in step 10 under “Power Up” is met.
When the preset amount is met, the buzzer
sounds and the
End Service
and ENTER LEDs
light.
4. Press ENTER to confirm that the correct
amount of ATF has been replaced.
Check
Trans Level
LED lights.
Check the ATF Level in the Pan
1. Remove the flexible nylon transfer hose.
2. Insert the dipstick.
3. Remove the dipstick to check fluid level.
If the fluid level needs to be adjusted, continue
on to Adjust the ATF Level. If the level is
satisfactory, go to step 4 under Adjust the ATF
Level.
Adjust the ATF Level
1. Place the flexible nylon hose in the dipstick
tube.
Note: An alternative method is to disconnect
the red hose from the dipstick wand
assembly, and connect it to the selector
valve assembly.
2. Press ENTER. The
To Trans
,
From Trans
and
Finish
LEDs light.
a. If the level is too low, select
To Trans
LED. Press ENTER. Press the up arrow key
to select how much fluid to add (each press
indicates one-tenth of a quart).
b. If the level is too high, select
From Trans
LED. Press ENTER. Press the up arrow key
to select how much fluid to take out (each
press indicates one-tenth of a quart).
3. When transfer is complete, go to Check the
ATF Level in the Pan.
4. If the level is satisfactory, press SELECT
until
Finish
LED lights.
a. Wait for one second.
b. Press ENTER to confirm the function.
c. Press ENTER again.
The display reads SR FIN, indicating the service
is finished.
Dipstick/Cooler Mode
continued
Red Hose
Selector Valve
Assembly
Adapters