117
Parameter List
Parameter List
4
DRIVING THE MOTOR
Offline auto tuning
458
Second motor constant
(R1)
0.001Ω 9999
0 to 50Ω
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
459
Second motor constant
(R2)
0.001Ω 9999
0 to 50Ω
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
460
Second motor constant (L1)
0.001
Ω
(0.1mH)
9999
0 to 50
Ω
(0
to 1000mH)
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
461
Second motor constant (L2)
0.001
Ω
(0.1mH)
9999
0 to 50
Ω
(0
to 1000mH)
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
462
Second motor constant (X)
0.01Ω
(0.1%)
9999
0 to 500Ω
(0 to 100%)
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
463
Second motor auto tuning
setting/status
1 0 0, 1, 101
Set the tuning mode of the second motor. (same as
Pr. 96)
684
Tuning data unit switchover
10
0 Internal data converter value
1 Displayed in "A, Ω, mH, %".
859
Torque current
0.01A 9999
0 to 500A
Tuning data
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
860
Second motor torque
current
0.01A 9999
0 to 500A
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
—
89
Refer to Pr. 81.
90 to 94
Refer to Pr. 82 to Pr. 84.
Online auto tuning
95
Online auto tuning selection
10
0 Online auto tuning is not performed
1 Start-time tuning (at start-up)
2 Magnetic flux observer (normal)
574
Second motor online auto
tuning
100, 1
Select the second motor online auto tuning. (same as
Pr. 95)
—
96
Refer to Pr. 82 to Pr. 84.
Func
t
ion
Parameter
Name
Incre
ments
Initial
Value
Range Description
Related
parameters
Magnetic flux
Magnetic flux
Sensorless
Sensorless Vector
Vector
Magnetic flux
Magnetic flux
Sensorless
Sensorless Vector
Vector