A SERVICE OF

logo

Item
Condition
Measurement Adjustment
Specifications/
Remarks
Test-
equipment
Unit Terminal PartsUnit Method
PC test modePanel tuning mode
ADJUSTMENT
NX-800
61
7. High RSSI at
-80dBm
adjust *8
[Analog
Narrow]
[Analog
Wide]
[NXDN Very
Narrow]
8.
Tight Squelch
adjust
(Squelch
level 9
adjust)
[Analog
Narrow]
[Analog
Wide]
1)
Adj item:[An HRSSI]
Adjust:[***]
2) Adj item:
[AnL HRSSI]
[AnL’ HRSSI]
[AnC HRSSI]
[AnH’ HRSSI]
[AnH HRSSI]
SSG output :
-80dBm
(22.4µV)
(MOD: 1kHz,
Dev: ±1.5kHz)
1) Adj item:[Aw R
HRSSI]
Adjust:[***]
2) Adj item:
[AwL HRSSI]
[AwL’ HRSSI]
[AwC HRSSI]
[AwH’ HRSSI]
[AwH HRSSI]
SSG output :
-80dBm
(22.4µV)
(MOD: 1kHz,
Dev: ±3kHz)
1)
Adj item:[Nv HRSSI]
Adjust:[***]
2) Adj item:
[NvL HRSSI]
[NvL’ HRSSI]
[NvC HRSSI]
[NvH’ HRSSI]
[NvH HRSSI]
SSG output :
-80dBm
(22.4µV)
(MOD: 1kHz,
Dev: ±1.5kHz)
1) Adj item:[An SQLT]
Adjust:[***]
2) Adj item:
[AnL SQLT]
[AnL’ SQLT]
[AnC SQLT]
[AnH’ SQLT]
[AnH SQLT]
SSG output:
12dB SINAD level +6dB
(MOD: 1kHz,
Dev: ±1.5kHz)
1)
Adj item:[Aw SQLT]
Adjust:[***]
2) Adj item:
[AwL SQLT]
[AwL’ SQLT]
[AwC SQLT]
[AwH’ SQLT]
[AwH SQLT]
SSG output:
12dB SINAD level +6dB
(MOD: 1kHz,
Dev: ±3kHz)
1) Adj item:[High RSSI
(Narrow)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
-80dBm
(22.4µV)
(MOD: 1kHz,
Dev: ±1.5kHz)
1) Adj item:[High RSSI
(Wide)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
-80dBm
(22.4µV)
(MOD: 1kHz,
Dev: ±3kHz)
1) Adj item:[High RSSI
(Very Narrow)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
-80dBm
(22.4µV)
(MOD: 1kHz,
Dev: ±1.5kHz)
1) Adj item:[Tight
Squelch (Narrow)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
12dB SINAD level +6dB
(MOD: 1kHz,
Dev: ±1.5kHz)
1) Adj item:[Tight
Squelch (Wide)]
2) Adj item:[Low]
[Low’]
[Center]
[High’]
[High]
SSG output :
12dB SINAD level +6dB
(MOD: 1kHz,
Dev: ±3kHz)
SSG
SSG
AF VTVM
Oscilloscope
Distortion
meter
Dummy
load
ANT
Ext.SP
connector
[Panel test mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the
adjustment value.
Adjust with the
analog signal.
*8: Because “RSSI at -80dBm adjust” of NXDN Narrow is adjusted by adjusting “RSSI at -80dBm adjust [Analog Narrow]”, it is not necessary to adjust
“RSSI at -80dBm adjust” of NXDN Narrow.