Remove On/Off Module as a Controller of Multiple Responders
1) Press and hold On/Off Module set button until it beeps
LED will start blinking green
2) Press and hold On/Off Module set button until it beeps a second time
LED will start blinking red
3) Tap On/Off Module set button
LED will start double-blinking red
4) For each responder you are removing:
a. Press and hold set button until it double-beeps
5) Tap On/Off Module set button
On/Off Module will beep and LED will stop blinking
6) Test by tapping On/Off Module paddle on and off
None of the former responders will respond
Factory Reset
All settings, links and scenes will be erased.
1) Press and hold On/Off Module set button until it beeps
LED will start blinking green
2) Press and hold On/Off Module set button until it beeps a second time
LED will start blinking red
3) Press and hold On/Off Module set button until it beeps a third time
LED will start blinking green
4) Slowly tap On/Off Module set button 3 times
LED will start double-blinking green
5) Press and hold On/Off Module set button. Do not let go.
On/Off Module will begin to emit a long beep
6) After beep stops, release On/Off Module set button
After a few seconds, On/Off Module will double-beep
X10 Setup
On/Off Module ships with no X10 address assigned.
Add X10 Address
1) Press and hold set button until it beeps
LED will start blinking green
2) Send the X10 address 3 times (with or without commands)
Example: A1-AON-A1-AON-A1-AON or A1-A1-A1-AON
On/Off Module will double-beep and LED will stop blinking
3) Test by sending X10 on and off commands
Load will turn on and off
Remove X10 Address
1) Press and hold set button until it beeps
LED will start blinking green
2) Press and hold set button until it beeps a second time
LED will start blinking red
3) Send the X10 address 3 times (with or without commands)