Zenoah EBZ8000 Blower User Manual


 
Mist Kit for EBZ8000 / EBZ8001
GB-7
G
B
Discharge rate
Valve travel (lit/min.)
1 1.0
2 2.1
3 3.8
4 5.5
Max. Longitudinal coverage
Horizontal direction : 22 m
Vertical direction : 14 m
5. Operation
HOW TO USE
1. Pour the solution into the tank with the intermediate
valve closed.
WARNING
Do not fill chemicals over 14 liters.
Do not mix different chemicals.
2. Adjust the solution flow and the spray range accord-
ing to work conditions.
The solution flow is changed by shifting the number
on the top of the valve at the mist nozzle. The figure
shows 5.5 lit/min. position.
The spray range is changed by shifting the bell posi-
tion after loosening the lock ring.
(A) Pulled out position: Long distance, narrow angle spray
(B) Pushed In position: Short distance, wide angle spray
3. Start the engine and carry the unit on your back.
4. While holding the swivel joint in your right hand, move
the throttle lever upward and turn the intermediate
valve to the open position.
5. After spraying work has finished, close the intermedi-
ate valve and stop the engine.
WARNING
Before the solution spraying work, supply water into
the tank and operate the mister to make sure that there
is any leakage or any mechanical failure.
Repair it if there is any leakage or failure before the
solution spraying work.
6. Maintenance
WARNING
Make sure that the engine has stopped and is
cool before performing any service to the
blower. Contact with rotating blower fan or hot
muffler may result in a personal injury.
Use only ZENOAH replacement parts. Failure to do
so may cause poor performance, possible injury and
may void your warranty.
Inspect unit before each use for loose fasteners,
leaks, etc. Replace damaged parts.