Zenoah EBZ8000 Blower User Manual


 
Mist Kit for EBZ8000 / EBZ8001
GB-6
4. Set up
ASSEMBLY
1. Remove the back pad from the back plate.
(1)
(2)
2. Fit frame (D) in the groove of the back plate, and fas-
ten it with 2 plates (G) and 6 screws (L).
3. Fasten the spacer (H) with 2 screws (K) .
4. Replace the back pad.
(L)
(G)
(K)
(L)
(H)
(L)
(G)
(L)
(D)
5. Set the tank (A) as shown in the picture, and fasten it
with the plate (E), 2 plates (F) and 4 screws (J) .
6. Connect the tube (M) to the volute and tank (A) , and
fasten it with 2 clips (N) .
(F)
(F)
(J)
(J)
(E)
(A)
(N)
(M)
(N)
(1)
7. Connect the mist nozzle ass’y (C) with the pipe (I) .
8. Connect the valve ass'y (B) to the tank (A) and mist
nozzle ass'y (C) , and fix them with 2 clips (N) .
(N)
(B)
(N)
(C)(I)
TIGHTENING TORQUE
3.5 ± 0.5 N·m
COMPONENTS (pcs.)
(A) Tank Ass’y ............. 1
(B) Valve Ass’y............ 1
(C) Mist Nozzle Ass’y.. 1
(D) Frame.................... 1
(E) Plate ...................... 1
(F) Plate ...................... 2
(G) Plate ...................... 2
(H) Spacer .................. 1
(I) Pipe....................... 1
(J) Screw 5 x 14 ......... 4
(K) Screw 5 x 20 ......... 2
(L) Screw 5 x 25 ......... 6
(M) Tube ...................... 1
(N) Clip ....................... 4
(O) Clamp ................... 1
(A)
(B)
(C)
(E)
(F)
(G)
(H)
(J)
(K)
(L)
(D)
(I)
(M)
(N)
(O)
(1) Volute
(1) Back plate
(2) Back pad