Important Installation and Utility Information
Electrical Service:
110V: 110V, 60 Hz, 2.75 A mp GFCI protected grounded circuit must be used to supply pow er to the
pedicure spa. (220V if ordered in 220V configuration)
220V: 220V, 50/60 Hz, 2.75 Amp GFCI protected grounded circuit must be used to supply pow er to the
pedicure spa.
Water Supply:
All plumbing connections must conform to local codes.
Normal w ater pressure of 30 to 80 PSI is required to correctly fill the basin to the proper level.
Maximum operating w ater temperature should not exceed 105
°
F (41
°
C) and the maximum supply water
temperature should not exceed 150
°
F (65
°
C). (In Massachusetts, the maximum supply water temperature
should not exceed 130
°
F (54
°
C)). Adjust your hot water heater accordingly.
For hot and cold w ater supply fittings and pow er drain fittings location, see figure 1 below .
Carefully connect the incoming w ater supply lines to the appropriate fittings located on the back of the
pedicure spa. Shut-off valves are recommended.
The pedicure spa drain must meet local plumbing codes. Check valve for drain are not provided and
must be installed by a licensed plumber, if required by Local or State codes.
**Note: See local and state codes as to what type of drain connection is required to be made.
Note: Not using the supplied bulkhead fittings will result in NO backflow protection.
Check your Local & State plumbing codes for additional backflow requirements.
Backflow Protection Devices for Faucets with Side Spray: Check valves comply with ANSI/ASME
A112.18.3M, A112.18.1M, CSA B125, and NSF 61
ANSI/ASME A112.18.3M (Performance Requirements for Backflow Protection Devices and Systems in
Plumbing Fixture Fittings) is applicable to plumbing fixture fittings w ith outlets not protected by an air gap.
Included in the possible range of applications are fittings with hose connected outlets, fittings w ith pullout
spout, hand held show ers, shampoo fittings and deck- mounted fittings. ASME A112.18.3M is now
referenced in ASME A112.18.1M (Plumbing Fixture Fittings) and CSA B125. Check valves are listed to both
standards w ith the Canadian Standards Association, IAPMO and UL.
AN S I - American National Standards Institute
ASME - American Society of Mechanical Engineers
CSA - Canadian Standards Association
IAPMO - International Association of Plumbing and Mechanical Officials
UL - Underwriters Laboratory
TÜV - Technischer Überwachungs-Verein “Technical Watch-Over Association”
Hot & Cold supply
fittings contain Neoperl
®
DW15GF check valves.
See figure 1 for proper
flow direction.
Plumbing Connections
(does not have c heck valve)
Back of Pedicure Spa
Figure 1