Toavoid engine problems, empty the fuel sys-
tem before storage for 30 days o r longer.
Drain the gas tank, start the engine and let it
run until the fuel lines and carburetor are
empty. Use fresh fuel next season.
Never use engine orcarburetor cleaner prod-
ucts in the fuel tank or permanent damage
may occur. See the STORAGE section for
additional information.
HOW TO STOP YOUR UNIT
S
To stop the engine, push and release the
engine ON/STOP switch. The switch will
automatically return to the ON position.
Wait 5 seconds before attempting to restart
unit to allow switch to reset.
S
If engine does not stop, move choke lever
to FULL CHOKE position.
Engine
ON/STOP
Switch
Choke Lever
FULL
HALF
OFF
HOW TO START YOUR UNIT
WARNING:
The trimmer head will
turn while starting the engine. Avoid any con-
tact with the muffler. A hot muffler can cause
serious burns.
STARTING A COLD ENGINE (or a
warm engine after running out of
fuel)
Starting Position
1. Setunitonaflatsurface.
2. Slowly press the primer bulb 6 times.
3. M ove choke lever to the FULL CHOKE
position.
4. Squeeze the throttle trigger fully and hold
through
all r emaining steps.
Choke
Lever
Primer Bulb
Starter Handle
Muffler
5. Pull starterrope handle sharply until engine
sounds as if it is trying to start, but do not
pull r ope more than 6 times.
6. As soon as engine sounds as if itis tr yingto
start, move choke lever to HALF CHOKE
position.
7. Pull starter rope sharply until engine runs,
but no more than 6 pulls.
NOTE:
If the engine doesn’t start after 6
pulls (at the HALF CHOKE position),
move the choke lever to the FULL
CHOKE position and press the primer
bulb 6 times. Squeeze and hold the
throttle trigger and pull the starter rope 2
more times. Move the choke lever to the
HALF CHOKE position and pull the start-
er rope until the engine runs, but nomore
than 6 pulls. If the engine still doesn’t
start, it is probably flooded. Proceed to
STARTING A FLOODED ENGINE.
8. Once theenginestarts, allowit to run 10se-
conds, then move the choke lever to the
OFF C H O KE position. Allow the unit to run
for 30 mor e seconds at O FF C H OKE be-
fore releasing the thr ottle trigger.
NOTE:
If engine dies with the choke le-
ver in the OFF CHOKE position, move
the choke lever to the HALF CHOKE
position and pull the rope until engine
runs, but no more than 6 pulls.
STARTING A WARM ENGINE
1. Move the choke lever to the HALF
CHOKE position.
2. Squeeze and hold the throttle trigger.
Keep throttle trigger fully squeezed until
the engine runs smoothly.
3. Pull starter rope sharply until engine runs,
but no more than 5 pulls.
4. Allow engine to run 15 seconds, then
movethe choke lever tothe OFFCHOKE
position.
NOTE:
If engine has not started, pull start-
er rope 5 more pul ls. If engine still does not
run, it is probably flooded.
STARTING A FLOODED ENGINE
Flooded engines can be started by placing
the choke lever i n the O FF CHOKE position;
then, pull the rope to clear the engine of ex-
cessfuel. Thiscould r equirepulling thestarter
handle many times depending on how badly
the unit is flooded.
If the unit still doesn’t start, refer to
TROUBLESHOOTING TABLE or call
1-800-554--6723.
OPERATING POSITION
Eye
Protection
Long Pants
Heavy Shoes
ALWAYS WEAR:
Cut from your left to your right.
WARNING:
Always wear eye protec-
tion. Never lean over the tr immer head. Rocks
or debris can r icochet or be throw n into eyes
and face and cause blindness o r other ser ious
injur y.