Vector VEC097 Portable Generator User Manual


 
11
5.3 Operating Time
Vector recommends that the operator recharge the battery system as frequently
as possible using the supplied VEC077EM Battery Charger. This will guard
against any unexpected shutdown of the equipment and will ensure that there
is always sufficient battery capacity. The inverter will sound it’s alarm when
DC voltage drops to 10.5 Volts.
5.4 Powering an AC Load
The Power Inverter is equipped with a dual GFCI receptacle and On/Off Switch.
Plug the power cord from the equipment you wish to operate into the AC
receptacle. The green LED will light to indicate that the unit is functioning.
Make sure the wattage rating of your equipment is within 1800 watts. If so,
turn on your equipment. If an audible alarm sounds, the DC supply voltage
may be too low, and the battery needs to be recharged.
Do not connect to AC distribution wiring: the inverter is engineered to be
connected directly to standard electrical and electronic equipment in the
manner described above. Do not directy wire the power inverter to household
or RV AC distribution wiring. You may use extension cords and outlet strips.
CAUTION: RECHARGEABLE APPLIANCES
Certain rechargeable devices are recharged by plugging them directly into
an AC receptacle. When first using a rechargeable device, monitor its
temperature for the initial ten minutes of use to determine whether it becomes
warmer than usual. If excessive heat is generated, it is a good indication that
the device should not be used with this inverter. This problem does not occur
with the majority of battery-operated equipment. Most of these devices use a
separate charger or transformer that is plugged into an AC receptacle. This
inverter is easily capable of powering most chargers and transformers.
5.5 Placement of ElectroMate
For best operating results, keep in mind that the Inverter will generate heat –
the larger the AC load the more heat generated. Therefore, the user should try
to use ElectroMate in a cool dry place out of sunlight, if possible.
WARNING: NEVER OPERATE ELECTROMATE WITH THE PLASTIC DUST
COVER ON. REMOVE THE DUST COVER BEFORE OPERATING
ELECTROMATE.
WARNING: Inverters generate heat while operating. Power inverters
should only be used in locations that meet the following criteria:
DRY - Do not allow water or other liquids to come into contact with the
inverter.
COOL - Ambient air temperature should be between 30 degrees F
(-1 degree C) non-condensing, and 100° F (38° C).
VENTILATED - Keep the area surrounding the inverter clear to ensure free air
circulation around the unit. Do not place items on or over the inverter during
operation. Therefore, remove the plastic dust cover before operating the sys-
tem. The unit will shut down if the internal temperature gets too hot. Restart the
unit after it cools.