Unigreen 20 Spreader User Manual


 
7
FIG. 1
TYPE : .......................................................................
code: ........................................ N˚ ...........................
massa a vuoto: ..........................Kg. max press. : ........... bar
net mass
massa totale ammessa: .............................. Kg.
total mass
via Rinaldi, 105 - Reggio Emilia ITALIA
ANNO
YEAR
20 .......
made in
Italy
2.4.1 TAKING PRECAUTIONS AGAINST FIRE HAZARDS
Don’t use naked flames or heat sources near the machines.
The sprayers are made with many materials that derive from petroleum: tanks,
tubes, pipes and hoses, wheels and plastic parts; furthermore the presence of
oils of various nature and residues of chemical products make them potentially
flammable.
2.5 MACHINES DESIGNED TO BE USED ONLY WITH CLEAN WATER
There are versions of the machines designed only to be used with a hose reel
for washing with cold clean water.
These machines cannot be used with chemical products as they don’t have
some of the devices or accessories that are needed to use these products
safely. These machines are identified by the word “washing” on the CE plate.
2.7 WEATHER CONDITIONS
We recommend spraying in the early hours of the morning or late in the
afternoon, avoiding the hottest time of day.
Never do any spraying if it’s raining or rain is forecast.
Don’t spray in strong wind or in any case, in winds above 3/5 m/second.
If you have to spray in windy conditions, use relatively low pressures to obtain
quite large drops that are less sensitive to drifting (being heavier the wind has
less effect). There are also special anti-drift nozzles available from UNIGREEN
S.p.A.; for information, please contact our offices.
2.8 ROAD CIRCULATION
The admissible capacity of the vehicle (pickup or truck) or the trailer upon which
the equipment is positioned should be checked.
The equipment is supplied for application to the floor. In the case of fixed rigging
the vehicle needs to be registered.
You need to check the correct couplings with your area dealer.
3 CHARACTERISTICS AND SPECIFICATIONS
3.1 MACHINE IDENTIFICATION
This handbook is valid for UMP-MASTER sprayers to be used for:
a) treatments with hand lances with or without a hose reel
b) hand lances for washing with or without a hose reel
The UNIGREEN S.p.A. sprayers are identified by the CE plate (FIG. 1 ) bearing
one of the marks indicated in the tables of the allowed fittings (TABLE N° 10 ,
page 19).
3.2 TABLES OF FITTINGS ALLOWED
Table N° 10 let you identify the version of your machine indicating the basic
equipment and all the possible fittings available (optional).
You can also find the other fittings allowed or other versions to meet your
requirements in the future.
THE FITTING DEFINED IN TABLE N° 10 (PAGES 19) SHOULD BE
CONSIDERED BINDING FOR THE VALIDITY OF THE DECLARATION OF
CONFORMITY.
Other fittings or setups of basic components and optionals should be
considered unsafe and therefore are not covered by the guarantee and aren’t
UNIGREEN’s responsibility.
The same goes for fittings realised with components or accessories that aren’t
original UNIGREEN parts.
UNIGREEN accessories can easily be identified by the label with the yellow
background “ORIGINAL UNIGREEN ACCESSORY”
3.3 NOISE LEVEL OF THE MACHINE
Use earmuffs to protect your ears when using the machine, the multi-purpose
Units produce a maximum level of sound pressure inferior to 89 dB (A) and a
level of power inferior to 107Db (A).
Readings taken in accordance with the following standards:
Machines Directive 98/37/CE (Ex. Dir.89/392 CE).
Legislative Decree D.Lgs. n°292 of the 4th of September 2002 concerning the
environmental acoustic emission of machines and equipment for use outdoors.
Legislative Decree D.Lgs. 277/91 on the subject of the protection of workers
against the risks deriving from exposure to chemical, physical and biological
agents.