Troy-Bilt TB250B Blower User Manual


 
13
MAINTENANCE AND REPAIR INSTRUCTIONS
REPLACING THE SPARK PLUG
Use a Champion RDJ7Y spark plug, or equivalent. The
correct air gap is 0.020 inch (0.5 mm). Remove the plug
after every 25 hours of operation and check its condition.
1. Stop the engine and allow it to cool. Grasp the plug
wire firmly and pull it from the spark plug.
2. Clean around the spark plug. Remove the spark plug
from the cylinder head by turning a 5/8-inch socket
counterclockwise.
3. Replace a cracked, fouled or dirty spark plug. Set
the air gap at 0.020 in. (0.5 mm) using a feeler gauge
(Fig. 15).
4. Install a correctly-gapped spark plug in the cylinder
head. Tighten by turning the 5/8-inch socket
clockwise until snug.
If using a torque wrench torque to:
110-120 in.•lb. (12.3-13.5 N•m)
Do not over tighten.
0.020 in.
(0.5 mm)
Fig. 15
Do not sand blast,
scrape or clean
electrodes. Grit in the engine could damage
the cylinder.
WARNING:
CLEANING THE UNIT
Use a small brush to clean off the outside of the unit.
Do not use strong detergents. Household cleaners that
contain aromatic oils such as pine and lemon, and
solvents such as kerosene, can damage plastic housing
or handle. Wipe off any moisture with a soft cloth.
STORAGE
Never store a fueled unit where fumes may reach an
open flame or spark.
Allow the engine to cool before storing.
Store the unit locked up to prevent unauthorized use
or damage.
Store the unit in a dry, well-ventilated area.
Store the unit out of the reach of children.
LONG TERM STORAGE
If you plan on storing the unit for an extended time, use
the following storage procedure:
1. Drain all fuel from the fuel tank into a container with
the same 2-cycle fuel mixture. Do not use fuel that
has been stored for more than 60 days. Dispose of
the old fuel/oil mix in accordance to Federal, State
and Local regulations.
2. Start the engine and allow it to run until it stalls. This
ensures that all fuel has been drained from the
carburetor.
3. Allow the engine to cool. Remove the spark plug and
put 1 oz. (30 ml) of any high quality motor oil or
2-cycle oil into the cylinder. Pull the starter rope
slowly to distribute the oil. Reinstall the spark plug.
NOTE: Remove the spark plug and drain all of the oil
from the cylinder before attempting to start the
unit after storage.
4. Thoroughly clean the unit and inspect it for any loose
or damaged parts. Repair or replace damaged parts
and tighten loose screws, nuts or bolts. The unit is
ready for storage.
TRANSPORTING
Allow the engine to cool before transporting.
Drain fuel from unit.
Tighten fuel cap before transporting.
Secure the unit while transporting.
ACCESSORIES/ REPLACEMENT PARTS
2-Cycle Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147543
Spark Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610311
Fuel Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180000
For specific replacement parts, refer to the parts list
located on the inside back cover of this manual.
To avoid serious
personal injury,
always turn your unit off and allow it to cool
before you clean or service it.
WARNING: