hours or minutes depending on the setting of the report interval units (19)
15) Report output interval LO, sets the automatic data dump interval to the RS232. Value can be
in minutes or seconds depending on the setting of the report interval unites (19).
16) Report Min/Max turns on the min-max function for the log and the report output (for the printer).
17) Report end of day- sends a formfeed at midnight to the RS-232 (for the printer).
18) Report Interval Units sets the ouput values to minutes or seconds.
19) Sets which command the report output will use, r, R, q or Q.
20) Sets the years..
21) Sets the month.
22) Sets day of month.
23) Sets the day of the week. (1=Sunday, 2=Monday, 3= Tuesday, 4=Wednesday, 5=Thursday, 6=
Friday, 7=Sunday)
24) Sets hours in 24 hour format..
25) Sets minutes
26) Sets Seconds.
27) Sets the logging interval hours (saves data in the units memory when set)
28) Sets the logging interval minutes.
29) 0 for English or 1 for Metric scale
30) Sets the ID number (0 through 255)
31) Displays number of power ups (0 through 255)
32) Displays the rainfall rate interval in minutes.
33) Wind Speed scale, changes wind speed to knots when set to 1. A 0 setting when in English will
output miles per hour and a 0 when in metric will output kilometers per hour.
34) Time display, when set to 0 the unit will display time in a 24 hour military format. When set to 1
the unit will be in AM or PM.
35) Aux disable, when set to 0 will cycle the temperature display through three values, indoor
temp, outdoor temp and the aux value (aux temperature or solar). When Aux disable is set to 1 the
temperature display will cycle through indoor and outdoor temperatures only.
36) Wind speed and direction, when set to 0 the unit outputs one minute average wind data to the
RS-232 port. When set to 1 the output is instant. This setting does not effect the display which has
its own button.
37) Selects baud rate, 0=38.4 1=19.2, 2=9600, 3=4800, 4=2400, 5=1200, 6=600, 7=300.
(Warning! Do not change this number unless you understand that you will lose
communication with the WRL until the host baud rate is also changed. Also note that
TWI_LOG does not support a baud rate fo 38.4.)
Pressing F6 will graph the data, if you have a VGA monitor.
Pressing F7 will take the current binary data file and convert it to a text file. The text file will be
named prn_day.??? for the minimums and maximums and prn_rec.??? for the record. The
extension of the files will correspond with the ID number of the weather unit whose record is being
converted.
Pressing F8 will display the version number of the firmware in the WRL.
Pressing F9 will set the weather station time to match that of the computer.