4
GENERAL INFORMATION
• Clean a new pool as well as possible before filling pool and operating filter.
Excess dirt and large particles of foreign matter in the system can cause seri-
ous damage to the filter and pump.
• With a diatomaceous earth (DE) filter system in place and operating cor-
rectly, clean water is returned to the pool faster than pool water is being
contaminated. A typical pool installation will require approximately one
week to obtain and maintain the sparkle that your filter is capable of giving
you.
• DO NOT use more than the recommended amount of DE in your filter. To
do so can cause a buildup of DE and "bridging" between the elements
which will plug the filter.
If filter is improperly disassembled or assembled, it can explode under
pressure! To avoid danger of severe injury or major property damage,
always follow service instructions in this manual when working on filter!
NEVER operate this filter system at more than 50 pounds per square
inch (50 PSI/345kPa) pressure! Be sure filter pressure gauge operates
when system is operating. If pressure gauge is damaged or does not work, re-
place it.
Purge all air from system before operating system. NEVER operate filter
with air trapped inside.
• On a new pool installation, we recommend:
1. Disassemble the filter after the initial cleanup.
To prevent severe injury or major property damage, exactly follow "Filter
Disassembly/Assembly Procedure" on Page 8.
2. Remove and hose down the element assembly to remove contaminants.
• It is a good idea to remove the element assembly once a year and soak it in
a filter cleaning solution to remove accumulated body oils, etc.; see Page
11, "Chemical Cleaning Procedure".
• Cleaning interval is based on pressure differential, not on length of time fil-
ter is operated. Different water conditions will have different normal clean-
ing intervals. If backwashing filter is not possible, use "Manual Filter
Cleaning Procedure", Page 10, at regular intervals to clean filter.
• Check local codes for restrictions on backwash to waste piping, separation
tank requirements and spent D.E. disposal requirements.
Hazardous pressure.
Can cause severe
injury or major
property damage
from tank blow up.
Release all pressure
and read instructions
before working on filter.