Sears S2800 Portable Generator User Manual


 
12
0069439
GENERAL STORAGE GUIDELINES
WARNING: GASOLINE FUEL FUMES ARE
FLAMMABLE. DO NOT STORE YOUR GENSET IN
ANY AREA THAT IS INDOOR OR IN POORLY
VENTILATED AREAS. GASOLINE FUEL FUMES CAN
IGNITE IN THE PRESENCE OF ANY OPEN FLAME, PILOT
LIGHT, CLOTHES DRYER, WATER HEATER, ETC.
Your generator should be started and operated for
several minutes at least every 30 days. When the generator
set is not being operated or is being stored more than one
month, follow these instructions:
1. Replenish engine oil to upper level.
2. Run the generator, then close the fuel shut-off valve and
allow the unit to run until the engine stops.
3. Move the engine switch to the “OFF” position.
4. After the unit has cooled, drain gasoline from fuel tank,
fuel line and carburetor.
5. Pour about one teaspoon of engine oil through the spark
plug hole, pull the recoil starter several times and replace
the plug. Then pull the starter until you feel the piston is
on its compression stroke and leave it in that position. This
closes both the intake and exhaust valves to prevent the
inside of the cylinder from rusting.
6. Cover the unit and store in a clean, dry place that is well
ventilated away from open flame or sparks.
NOTE: We recommend always using a fuel stabilizer.
A fuel stabilizer will minimize the formulation of fuel gum
deposits during storage. The fuel stabilizer can be added
to the gasoline in the fuel tank, or into the gasoline in a
storage container.
English
GENERAL MAINTENANCE
Proper maintenance and service are required to achieve maximum engine life and maintain warranty. The following tables provide
engine specifications as well as maintenance schedules for the generator engines. Note that the generator models are
referenced with the engine model. An engine owner's manual is provided with each machine that also provides basic
maintenance and troubleshooting information. Defer to the engine manufacturers manual if any discrepancies appear between
the data provided in this manual and the engine owner's manual. Full engine service manuals are available from Subaru Robin
America Inc., 905 Telser Rd., Lake Zurich, IL 60047, Toll Free: (800) 277-6246, Tel: (847) 540-7300.
ENGINE SPECIFICATIONS AND CAPACITIES
Model SP170
Type
Air-cooled, 4-cycle, single cylinder, overhead camshaft,
gasoline engine
Displacement 169cc (10.3 cu in)
Maximum Torque 8.34ft-lb @2500rpm
Rated Output 5.7 HP @4000rpm
PTO Shaft Rotation Counterclockwise (from PTO side)
Lubricant
Automotive detergent oil (API/SE or higher grade, SAE
10W-30)
Oil Capacity 0.6 l (0.63 US qt)
Fuel Type Unleaded gasoline
Fuel Tank Capacity 3.4 l (0.9 US gal)
Spark Plug BR-6HS (NGK), E6RC (Torch)
Starting System Recoil
Dry Weight 15 kg (33 lb)
Dimensions (L x W x H) 12.2 x 14 x 13 in
Valve Clearance (Intake and Exhaust)
0.12 +0.03/0 mm (0.0047 +.0012/0 in)
Note: Adjust the valve clearance while the engine is
cold.
Emission Durability Period (California Only) 125 hours