Sanyo KS1852 Yard Vacuum User Manual


 
Special Remarks
‘‘DRY’’ ( ) Operation
How it works?
Once the room temperature reaches the level that was set, the unit
repeats the cycle of turning on and off automatically.
During DRY operation, the fan speed is automatically set to LOW or
VERY LOW; the fan speed then switches back and forth between LOW
(for 20 seconds) and VERY LOW (for 10 seconds).
‘‘DRY’’ operation is not possible if the indoor temperature is 59 °F or
less.
Power failure
during operation
In the event of power failure, the unit will stop. When the power is
turned on again, the unit restarts within five minutes.
Clicking Sound
Clicking sound is
heard from the air
conditioner
In cooling and drying operation, any plastic parts may expand or shrink
due to a sudden temperature change. In this event, a clicking sound
may occur. This is normal, and the sound will soon disappear.
Remote Control Unit
The remote control unit sends the setting condition to the air
conditioner regularly at five minute intervals.
IMPORTANT
KS1852 and CL1852
Combination
When this unit is combined with the CL1852 outdoor unit, set the indoor
airflow to medium or high when the outdoor temperature drops below
32 °F to prevent condensation from forming at the indoor unit.
15OI-330-15EG
oi330000