Ryobi Outdoor 510r Cultivator User Manual


 
MAINTENANCE AND REPAIR INSTRUCTIONS
15
Fig. 21
Fill Level
AIR FILTER MAINTENANCE
Cleaning the Air Filter
WARNING: To avoid serious personal injury,
always turn your unit off and allow it to cool
before you clean or do any maintenance on it.
Clean and re-oil the air filter every 10 hours of operation.
It is an important item to maintain. Not maintaining the
air filter will VOID the warranty.
1. Open the air filter cover. Push the tab on the left side
of the cover in, swing the air filter cover out and off
the air filter housing (Fig. 22).
2. Remove the air filter (Fig. 22).
3. Wash the filter in detergent and water (Fig. 23). Rinse
the filter thoroughly and allow it to dry.
4. Apply enough clean SAE 30 motor oil to lightly coat
the filter (Fig. 24).
Air Filter
Hooks
Slot
Choke Lever
Air Filter Cover
Air Filter Housing
Tab
Tab
Fig. 22
Fig. 23
Fig. 24
Fig. 25
5. Squeeze the filter to spread and remove excess oil
(Fig. 25).
6. Replace the filter (Fig. 22).
NOTE: If the unit is operated without the air filter, you
will VOID the warranty.
7. Reinstall the air filter cover. Position the hooks on
the right side of the air filter cover into the slots at
the right side of the air filter housing (Fig. 22).
8. Swing the cover to the left until the tab on the air
filter cover snaps into place in the slot on the left