2. GENERATOR TROUBLESHOOTING
2-1 NO AC OUTPUT
2-1-1 CHECKING CONDENSER
(1) Check the capacity of condensers using a “Dr. Robin” generator tester in capacitance meter mode.
NOTE : Be sure to discharge condensers by shorting condenser leads each other before checking their
capacitance, or the accurate reading cannot be obtained.
(2) If such an instrument is unavailable, the con-
denser can be checked by replacing with a
new one. If the generator performs good with
new condenser, the cause of trouble is defect
in original condenser.
2-1-2 CHECKING STATOR
(1) Remove control panel and disconnect stator
wires at the connectors.
(2) Measure the resistance between terminals on
stator leads. (See Fig.2-2) Refer to Table 2-2
for normal resistance.
If stator is faulty, replace it with a new one.
Fig. 2-2
COUPLER STATOR