10-4 Engine dose not run.
Symptom Possible causes Remedy
1. Electric starter
dose not operate
1) The key switch (or remote
switch) is turned to "START"
within 2 seconds the engine has
been stopped.
Wait for more than 2 seconds and then turn the
key switch to "START" position.
1) No fuel in the tank or the fuel
cock is closed.
2) The remote controller is con-
nected.
Both the key switch of the generator and the
switch of remote controller must be turns into
"ON" position.
3) The above possible causes 1)
and 2) dose not apply.
The ECU is defective.
Replace with new one.
2. Warning lamp
turns on and off
when engine is
stopped
Supply fuel or open the fuel cocks.
2) Oil level is low or oil is contami-
nated.
Add or change engine oil.
3. Engine is auto-
matically stopped
but the warning
lamp dose not
light up
1) The bulb of warning lamp failed. Replace the bulb with a new one.