8
WIRING
Connect positive terminal of the
electric starter and positive termi-
nal of the battery with battery
cable.
Ground negative terminal of the
battery to the body of engine or
machine with ground wire.
NOTE
Tighten bolts and nuts on terminals
securely so they will not be loosened
by vibration.
BATTERY
12V-30AH
+
-
ELECTRIC STARTER
TERMINAL
EARTH WIRE
CABLE
STOP
DIODE
S
B
M
G
L
CARBURETOR
REGULATOR
IGNITION
COIL
RED
GREEN
BATTERY
12V-30AH
+
-
KEY
SWITCH
CHARGE
COIL
BLACK
BLACK
BLACK
Key switch (Option parts)
GMB LS
OFF
Terminal
Key
Position
RUN
START
LA408
ELECTRIC
STARTER
OIL
PRESSURE
SWITCH
OIL
WARNING
LAMP
WIRING DIAGRAM
Optional hardware shown by dotted lines. Select wires of proper gauge and
connect battery as shown by the dotted line in the wiring diagram.
EH63-65 EPA/CARB 取説EU1728 02.7.31 10:30 AM ページ8