Standard Operation:
Wireless Monitor Status LED’s
t 5IFXJSFMFTTNPOJUPSSFDFJWFTEBUBGSPNUIFHFOFSBUPS
every 10 minutes and displays the generator status
through 3 LED’s.
t 1SFTTJOHUIFSYSTEM UPDATE button will provide
current generator status by flashing the status LED’s.
When pressed, all 3 LEDs will flash until the generator
status is received.
NOTICE Generator control panel must be in AUTO mode or
no communication with monitor will occur.
t *OPSEFSUPDPOTFSWFQPXFSBOEUPFYUFOECBUUFSZMJGF
the LED’s are not lit continuously; instead they are
briefly flashed as indicated below.
NOTICE During the weekly exercise cycle, the generator will
run for 20 minutes, but it will not supply power to the home.
During the exercise cycle, the monitor will continue blinking
the GENERATOR READY green LED.
t (&/&3"5033&"%:8IFOBDUJWFUIFHSFFO-&%XJMM
flash once every 7 seconds. The green LED indicates
that the generator is in AUTO mode and that it is ready
to run in the event of a loss of utility power.
t (&/&3"503108&38IFOBDUJWFUIFHSFFO-&%XJMM
flash every 7 seconds. The green LED indicates that the
generator is supplying power.
t 4&37*$&/&&%&%8IFOBDUJWFUIFSFE-&%XJMMGMBTI
in a sequence that corresponds to the service code.
For example, when Low Frequency scrolls across the
control board, the red LED will flash 5 times with a 3
second pause between series of blinks until it is reset
or the condition is corrected. When the red LED is lit,
contact your nearest authorized service dealer.
NOTICE None of the conditions on the display unit can be
cleared at the wireless monitor. All alerts must be cleared at
the generator control panel.
NOTICE Service conditions will only be displayed on the
basic monitor when the control board is placed in AUTO
mode.
Other:
LED Lighting Codes
t #BUUFSJFT*OTFSUFEGENERATOR READY LED will light
for 5 seconds.
t 8JSFMFTT$PNNVOJDBUJPO-PTUSERVICE NEEDED LED
will flash 20 fast pulses, then pause for 5 seconds, and
repeat the sequence until the communication has been
restored.
NOTICE Communication lost issues can typically be
resolved by moving the wireless monitor closer, within the
home, to the standby generator.
t -JOLJOH&SSPSPS/PU-JOLFESERVICE NEEDED
LED will light for 4 seconds, pause for 4 seconds,
and repeat the sequence until a successful link is
completed.
Installation Inspection
Before placing the generator system into service, inspect the
entire installation carefully.
This completes the installation and start-up instructions.
The operator’s manual provides full details on Operation,