RedMax EBZ5100Q Blower User Manual


 
46
Case 1. Starting failure
CHECK PROBABLE CAUSES ACTION
fuel tank incorrect fuel drain it and with correct fuel
fuel filter fuel filter is clogged clean
carburetor adjustment screw out of normal range adjust to normal range
sparking (no spark) spark plug is fouled/wet clean/dry
plug gap is incorrect correct (GAP: 0.6 – 0.7 mm)
spark plug disconnected retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK PROBABLE CAUSES ACTION
fuel tank incorrect fuel or staled fuel drain it and with correct fuel
carburetor adjustment screw out of normal range adjust to normal range
muffler,cylinder (exhaust port) carbon is built-up wipe away
air cleaner clogged with dust wash
cylinder fin, fan cover clogged with dust clean
When your unit seems to need further service, please consult with our service shop in your area.
English
12. Troubleshooting guide
Français
12. Guide de localisation des pannes
1er cas : Défaut de démarrage
VERIFICATION CAUSES PROBABLES ACTION
réservoir de carburant carburant incorrect vidanger et remplacer le carburant
filtre à carburant filtre à carburant colmaté nettoyer
vis de réglage de carburateur déréglé refaire le réglage
allumage bougie sale ou noyée nettoyer ou sécher
Jeu d’électrodes incorrect régler le jeu (de 0,6 à 0,7 mm)
Bougie d’allumage débrancher resserrer
2ème cas : Le moteur démarre mais ne reste pas en marche ou est difficile à redémarrer
VERIFICATION CAUSES PROBABLES ACTION
réservoir de carburant carburant incorrect vidanger et remplacer le carburant
vis de réglage de carburateur déréglé refaire le réglage
silencieux, cylindre dépôt de calamine retirer
filtre à air colmaté de poussière nettoyer
ailette de cylindre/flasque de ventilateur
colmaté de poussière nettoyer
Si la machine nécessite des opérations d’entretien plus élaborées, contacter le centre de service après-vente le plus proche.
Español
12. Guía de localización y solución de problemas
Caso 1. El motor no arranca
COMPROBAR POSIBLES CAUSAS ACCIÓN
Tanque de combustible Combustible incorrecto Vaciar y llenar con el combustible correcto
Filtro de combustible
El filtro de combustible está obstruido.
Limpiar
Tornillo de ajuste del carburador
Fuera del margen normal Ajustar al margen normal
Explosión (no hay chispa) La bujía está sucia/mojada. Limpiar/secar
La distancia interelectródica es incorrecta
Corregir (DISTANCIA INTERELECTRÓDICA: 0,6 – 0,7 mm)
Bujía Desconectada Reajustarlo
Caso 2. El motor arranca pero no se mantiene en marcha./Dificultad para volver a arrancar el motor.
COMPROBAR POSIBLES CAUSAS ACCIÓN
Tanque de combustible Combustible incorrecto
Vaciar y llenar con el combustible correcto.
Tornillo de ajuste del carburador Fuera del margen normal. Ajustar al margen normal.
Silenciador, cilindro (lumbrera de escape)
Acumulación de carbón Quitar
Filtro de aire Obstruido con polvo Lavar
Aletas del cilindro, cubierta de ventilador
Obstruidas con polvo Limpiar
Si le parece que la unidad necesita otros servicios, consulte nuestro centro de servicio en su área.