INDOOR HEATER
The design is also certified for indoor installation when equipped with the approved draft hood.
For Canada, indoor installation is restricted to an enclosure that is not occupied and does not directly
communicate with occupied area. Refer to the latest edition of CAN/CGA-B149.1 and B149.2 for specific
requirements.
Locate heater as close as practical to a chimney or gas vent. Heater must always be vented to the outside. See
Vent Piping Section for venting details. Minimum allowable space is shown on the nameplate.
11
OUTDOOR STACK / INDOOR STACK INSTALLATION
WARNING:
Indoor boilers require a drafthood that must be connected to a vent pipe and properly vented to the outside. Failure
to follow this procedure can cause fire or fatal carbon monoxide poisioning.
OUTDOOR KIT INCLUDES:
1- Draft hood, painted
1- Adapter plate
3- Mounting brackets
1- Top panel cover
2- 1 foot sections of metal tape
3- Screws
1- Instructions
Clips
Clips
INDOOR KIT INCLUDES:
1- Draft hood, unpainted
1- Adapter plate
3- Mounting brackets
3- Screws
1- Instructions
INSTRUCTIONS:
1. Make sure that the gas and electric has been
turned off to the unit.
2. Remove the "pagoda" top from the louvered top and
discard. See Fig. 3.
3. Remove the louvered top and set aside, saving the
four phillips screws for re-assembly. See Fig. 3.
4. Remove and discard the rain shield. See Fig. 4.
5. Install adapter plate on top of heater flue collector.
See Fig. 5.
6. Re-install louvered top on heater and fasten with
Phillips screws set aside in step 3.